Three methods compared for determination of pancreatic and salivary amylase activity in serum of cystic fibrosis patients.

نویسندگان

  • R O Wolf
  • V S Hubbard
  • B K Gillard
  • A Kingman
چکیده

We evaluated three methods for serum amylase (EC 3.2.1.1) isoenzymes to determine whether they are interchangeable and to test their ability to discriminate between cystic fibrosis patients with and without pancreatic insufficiency. One method involved salivary amylase inhibitor (O), and two were polyacrylamide gel electrophoresis separations differing in method of detection--either direct zymogram (G) or gel slicing followed by activity estimates per slice (W). Results for percentage pancreatic amylase differed significantly. Reproducibility for percentage pancreatic amylase was high, moderate, and low (r = 0.95, 0.53, and 0.02) for methods G, O, and W, respectively; moderate (r = 0.60) among the three methods; and moderate between pairs. Therefore, this result for a subject must be considered relative to the method used in its determination. The clinical diagnosis of pancreatic insufficiency was verified by 77.8%, 83.3%, and 94.4% correct classification rates for methods O, W, and G, respectively. Evidently, method G is the most efficient and may be the method of choice for measuring serum amylase isoenzymes in cystic fibrosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective deficiency of pancreatic amylase.

Two patients with specific pancreatic amylase deficiency are described. The greatly reduced pancreatic amylase activity was not due to an enzymatically inactive amylase molecule but to an almost complete absence of the molecule itself. The findings are of diagnostic importance as they show that low pancreatic amylase activity in serum or duodenal aspirates, or both, does not necessarily represe...

متن کامل

Differential serum amylase determination by use of an inhibitor, and design of a routine procedure.

We describe a new method for measuring pancreatic and salivary-type amylases in serum that requires no electrophoresis or chromatography. An inhibitor protein (from wheat) with a 100-fold greater specificity for human salivary than for human pancreatic amylase was used to analyze mixtures of the two enzymes. The concentration of pancreatic and salivary amyalase was determined in 141 normal sera...

متن کامل

Prevalence of Cystic Fibrosis Trans-membrane Conductance Regulator Gene common mutations in children with cystic fibrosis in Isfahan, Iran

Background: Cystic fibrosis (CF) is the most common lethal genetic disorder of Cystic Fibrosis Trans-membrane Conductance (CFTR) Regulator gene mutations. We aimed to investigate common mutations in CF patients and to assess its possible relationship with clinical presentations. Materials and Methods: This cross sectional study was conducted on 36 CF patients who were referred to a tertiary ped...

متن کامل

Determination of alpha-amylase activity: methods comparison and commutability study of several control materials.

Six different methods for alpha-amylase determination were compared by assaying human serum samples covering a wide range of alpha-amylase values. All the methods studied use as substrate a maltooligosaccharide with a chromophore group at the reducing end; some are chemically blocked at the nonreducing end. Intermethod comparison by regression and correspondence analyses showed significant diff...

متن کامل

Diagnostic use of pancreatic lipase determination by radial enzyme diffusion, and design of a routine pancreatic profile.

The differential diagnosis of diseases of the pancreas remains an acute problem area in medicine today. It can be stated with some certainty that no single test has the capability of 100% accuracy in the diagnosis of pancreatic disease, much less in the determination of the etiology of the condition. Basically, from the viewpoint of the clinical laboratory, inflammatory diseases of the pancreas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 1986