Assembly and RF Tuning of the IH-DTL for the HIT LINAC

نویسندگان

  • G. Clemente
  • H. Vormann
  • Y. Lu
  • S. Minaev
  • R. Tiede
  • B. Schlitt
  • R. Fuchs
چکیده

The 20 MV, 217 MHz IH-DTL for the HIT facility has been assembled and mechanically aligned until July 2006. RF tuning of the 3.8 m long tank with 56 gaps has been done from April to October 2006. The beam commissioning at the HIT facility in Heidelberg was performed successfully in December 2006. Assembly Alignment plates had to be invented to adjust the side walls of the middle frame against the stiff lower half shell of the tank. The copper plating of the cavity at GSI worked properly besides a rather thick layer on the sealings which resulted in a frequency shift of −0.7 MHz. The three quadrupole triplet lenses inside the tank are directly connected to the lower tank half shell. The maximum transverse deviations of individual quadrupoles amount up to ±0.2 mm after the final alignment – a factor of 2 more than specified but still tolerable, as checked by LORASR beam dynamics simulations (Fig. 1). We would like to thank our GSI colleagues T. Dettinger, N. Bönsch, J. Cavaco and N. Kischnick for their committed workmanship at copper plating and assembly. -10 -8 -6 -4 -2 0 2 4 6 8 10

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Status of the Linac for the Italian Hadron-Therapy Centre CNAO

The Italian hadron-therapy centre CNAO (Centro Nazionale di Adroterapia Oncologica) [1] is designed for the treatment of tumours with proton and light ion beams and to clinical and radiobiological research. The design consists of two ECR ion sources, a 7 MeV/u injector linac identical to the linac of the Heidelberg ion therapy centre HIT [2][3] and a 400 MeV/u synchrotron. GSI delivers technica...

متن کامل

Linac Commissioning for the Heavy Ion Cancer Therapy Facility HIT

The accelerator part of the clinical facility for cancer therapy HIT using energetic proton and ion beams (C, He and O) has been installed during 2006 at the Radiologische Universitätsklinik in Heidelberg, Germany [1]. The commissioning of the injector linac was performed in three steps for the LEBT, the RFQ and the IH-DTL and has successfully ended in December 2006. Some major results are brie...

متن کامل

Upgrade of the Isac Dtl Tuning Procedure at Triumf

The TRIUMF ISAC facility has two variable energy heavy ion linacs as post accelerators for radioactive ion beams. The ISAC I linac is a warm IH-DTL with five accelerating tanks and three bunchers, the ISAC II linac uses twenty independently phased superconducting cavities. The first linac operates between 150keV/u and 1.8Mev/u; the second boosts the 1.5MeV/u injected beam by 20MV. The DTL is tu...

متن کامل

Performances of the ISAC Heavy Ion Linacs

ISAC is the TRIUMF facility for the production and post acceleration of Rare Isotope Beams (RIBs). The post acceleration section includes two normal conducting linacs, an RFQ injector and a variable energy IH-DTL, and a superconducting linac composed of five cryomodules each containing four quarter wave bulk niobium resonators. All three machines operate CW. The RFQ and DTL deliver beam since 2...

متن کامل

The Spallation Neutron Source (sns) Linac Rf System*

The SNS is a spallation neutron research facility being built at Oak Ridge National Laboratory in Tennessee [1]. The Linac portion of the SNS (with the exception of the superconducting cavities) is the responsibility of the Los Alamos National Laboratory (LANL), and this responsibility includes the RF system for the entire linac. The linac accelerates an average beam current of 2 mA to an energ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007