Multi-coil MR imaging with a receive array of eight microcoils

نویسندگان

  • K. Kratt
  • E. Fischer
  • V. Badilita
  • M. Mohammadzadeh
  • J. Hennig
  • J. G. Korvink
  • U. Wallrabe
چکیده

Introduction Three-dimensional microcoils are used in medical technology for high-resolution magnetic resonance analysis at the micro level. The coil sensitivity, and therefore the desired signal, is maximized when the size of the coil matches that of the sample [1]. Micro solenoids show exceptional performance compared to planar coils and due to their 3-D shape, the B1 field is stronger and more uniform [2]. Difficult 3-D processes [3] or hand-made coils [4] prevented the production of suitable, reproducible, and economical coils. As devices are often single use, low-cost solutions are required. Receive coil arrays have been introduced in MRI to take advantage of improved local SNR in their reduced active volume. Parallel techniques lead to a reduction of phase gradient steps for imaging which eventually accelerates imaging acquisition [5]. In an arrangement of coils close to each other, mutual inductance leads to coupling between the coils. Therefore, coil decoupling needs to be done carefully. In case of microcoils, the corresponding sensitive volume is small, only extending around one to two coil diameters outside the coil volume. Consequently, arranging microcoils not too close to each other, mutual coil inductance can be neglected. We present an array of eight microcoils, which was produced using MEMS technology being therefore very cost-effective. It is a suitable environment for testing parallel excitation and simultaneous detection schemes suitable for high-throughput and disposable MR analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.

PURPOSE Magnetic resonance imaging (MRI) of rodents can be expected to be a growing application, particularly when translatory imaging research "from mouse to man" is envisioned. 7 T high-field human whole-body MR systems provide a powerful platform for high-resolution small animal imaging. For achieving adequate spatial resolution, dedicated radiofrequency coils have to be designed to provide ...

متن کامل

A magnetic resonance (MR) microscopy system using a microfluidically cryo-cooled planar coil.

We present the development of a microfluidically cryo-cooled planar coil for magnetic resonance (MR) microscopy. Cryogenically cooling radiofrequency (RF) coils for magnetic resonance imaging (MRI) can improve the signal to noise ratio (SNR) of the experiment. Conventional cryostats typically use a vacuum gap to keep samples to be imaged, especially biological samples, at or near room temperatu...

متن کامل

Multi-Reception Strategy with Improved SNR for Multichannel MR Imaging

A multi-reception strategy with extended GRAPPA is proposed in this work to improve MR imaging performance at ultra-high field MR systems with limited receiver channels. In this method, coil elements are separated to two or more groups under appropriate grouping criteria. Those groups are enabled in sequence for imaging first, and then parallel acquisition is performed to compensate for the red...

متن کامل

Receive Arrays and Circuitry

Receive coils are one of the most challenging components of the MR system, not only from a technical perspective but also because they are one of the few components in direct contact with the patient containing active electronic circuits. The proximity of the coil to the patient is a fundamental aspect in coil design, which is very often only associated to electronic design. During the past 15 ...

متن کامل

Design Criteria of an MR-PET Array Coil for Highly Parallel MR Brain Imaging

Introduction: Simultaneous acquisition of MR and PET images has the potential to combine high spatial resolution and high contrast MR data with specific functional molecular imaging in a wide range of clinical and research applications. Highly parallel MR imaging has proven valuable for increased image sensitivity and acquisition speed [1]. However, the development of a 32-channel brain array f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009