An Effective Measured Data Preprocessing Method in Electrical Impedance Tomography
نویسندگان
چکیده
As an advanced process detection technology, electrical impedance tomography (EIT) has widely been paid attention to and studied in the industrial fields. But the EIT techniques are greatly limited to the low spatial resolutions. This problem may result from the incorrect preprocessing of measuring data and lack of general criterion to evaluate different preprocessing processes. In this paper, an EIT data preprocessing method is proposed by all rooting measured data and evaluated by two constructed indexes based on all rooted EIT measured data. By finding the optimums of the two indexes, the proposed method can be applied to improve the EIT imaging spatial resolutions. In terms of a theoretical model, the optimal rooting times of the two indexes range in [0.23, 0.33] and in [0.22, 0.35], respectively. Moreover, these factors that affect the correctness of the proposed method are generally analyzed. The measuring data preprocessing is necessary and helpful for any imaging process. Thus, the proposed method can be generally and widely used in any imaging process. Experimental results validate the two proposed indexes.
منابع مشابه
A regularized Newton method in electrical impedance tomography using shape Hessian information
Abstract: The present paper is concerned with the identification of an obstacle or void of different conductivity included in a two-dimensional domain by measurements of voltage and currents at the boundary. We employ a reformulation of the given identification problem as a shape optimization problem as proposed by Roche and Sokolowski (1996). It turns out that the shape Hessian degenerates at ...
متن کاملThe Effect of Gold Nanoparticle on Electrical Impedance of Tissue on Low Frequency Ranges
Introduction: Electrical impedance of tissues on low frequencies includes useful information about functional and structural changes in tissues. This property is used in Electrical Impedance Tomography (EIT) imaging modality for the detection of lesions in tissues.Objective: The goal of this article is to study changes in electrical impedance of tissues in the presence of gold nanoparticles.Mat...
متن کاملApplications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملA uniqueness result and image reconstruction of the orthotropic conductivity in magnetic resonance electrical impedance tomography
The Magnetic resonance electrical impedance tomography (MREIT) is a new medical imaging method combining electrical impedance tomography (EIT) and current injection MRI technique. In this paper, we show the uniqueness in MREIT problem with an orthotropic conductivity under the hypothesis that the ratios of conductivities are known. Based on an effective numerical differentiation method and an a...
متن کاملModel-Aware Newton-Type Inversion Scheme For Electrical Impedance Tomography
Electrical impedance tomography is a non-invasive method for imaging the electrical conductivity of an object from voltage measurements on its surface. This inverse problem suffers in three respects: It is highly nonlinear, severely ill-posed and highly under-determined. To obtain yet reasonable reconstructions, maximal information needs to be gathered from the model and extracted from the data...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014