Differences in electron beam dosimetry using two commercial ionization chambers and the TG‐21 protocol: Another reason to switch to TG‐51
نویسندگان
چکیده
Two of the most popular dosimetry systems used for calibration of megavoltage photon and electron beams in radiation therapy are (i) cylindrical Farmer-type chambers in liquid water and (ii) Holt Memorial parallel-plate chambers in clear polystyrene. Since implementation of the AAPM TG-21 calibration protocol, the Radiological Physics Center (which uses the Farmer in-water system) has compared machine calibrations on two occasions with those of Memorial Sloan-Kettering Cancer Center (which uses the Holt in-polystyrene system). Two years post publication of the TG-51 protocol, 70% of the clinics monitored by the RPC still use TG-21. Seventeen photon beams from cobalt-60 to 18 MV and 31 electron beams from 6 to 20 MeV were compared using the TG-21 protocol. These data represent the most comprehensive comparison of the two most popular systems in use. Based on the average percent difference, the two systems yielded the same absorbed dose to water at the reference point in phantom to within 1.5% for both modalities. No energy dependence was evident in the results; however, a systematic average percent difference between photons and electrons was seen, with the Farmer in-water system consistently predicting a dose 1.3% lower for electrons than the Holt in-polystyrene system. For photons both systems predicted the same dose to within 0.3% on average. When a physicist converts from TG-21 to TG-51, these data may be of assistance in explaining unexpected changes in output that are different from previously published values. Implementation of the TG-51 protocol should eliminate any of the observed differences in electron beam dosimetry between the two dosimetry systems because the Holt system cannot be used with TG-51.
منابع مشابه
Comparison between TG‐51 and TG‐21: Calibration of photon and electron beams in water using cylindrical chambers
A new calibration protocol, developed by the AAPM Task Group 51 (TG-51) to replace the TG-21 protocol, is based on an absorbed-dose to water standard and calibration factor (N(D,w)), while the TG-21 protocol is based on an exposure (or air-kerma) standard and calibration factor (N(x)). Because of differences between these standards and the two protocols, the results of clinical reference dosime...
متن کاملComparison of the recommendations of the AAPM TG‐51 and TG‐51 addendum reference dosimetry protocols
This work quantified differences between recommendations of the TG-51 and TG-51 addendum reference dosimetry protocols. Reference dosimetry was performed for flattened photon beams with nominal energies of 6, 10, 15, and 23 MV, as well as flattening-filter free (FFF) beam energies of 6 and 10 MV, following the recommendations of both the TG-51 and TG-51 addendum protocols using both a Farmer® i...
متن کاملA Comparison of dosimetric parameters between IAEA TRS-398, AAPM TG-51 protocols and Monte-Carlo simulation
Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...
متن کاملTG‐51: Experience from 150 institutions, common errors, and helpful hints
The Radiological Physics Center (RPC) is a resource to the medical physics community for assistance regarding dosimetry procedures. Since the publication of the AAPM TG-51 calibration protocol, the RPC has responded to numerous phone calls raising questions and describing areas in the protocol where physicists have had problems. At the beginning of the year 2000, the RPC requested that institut...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کامل