Title Pulmonary blood flow evaluation using a dynamic flat - panel detector
نویسندگان
چکیده
Purpose Pulmonary ventilation and circulation dynamics are reflected on fluoroscopic images as changes in X-ray translucency. The purpose of this study was to investigate the feasibility of non-contrast functional imaging using a dynamic flat-panel detector (FPD). Methods Dynamic chest radiographs of 20 subjects (Abnormal, n=12; Normal, n=8) were obtained using the FPD system. Image analysis was performed to get qualitative perfusion mapping image; first, focal pixel value was defined. Second, lung area was determined and pulmonary hilar areas were eliminated. Third, one cardiac cycle was determined in each of the cases. Finally, total changes in pixel values during one cardiac cycle were calculated and their distributions were visualized with mapping on the original image. They were compared to the findings of lung perfusion scintigraphy. Results In all normal controls, the total changes in pixel value in one cardiac cycle decreased from the hilar region to the peripheral region of the lung with left-right symmetric distribution. In contrast, in many abnormal cases, pulmonary blood flow disorder was indicated as a reduction of changes in pixel values on a mapping image. The findings of mapping image coincided with those of lung perfusion scintigraphy. Conclusions Dynamic chest radiography using a FPD system with computer analysis is expected to be a new type of functional imaging which provides pulmonary blood flow distribution additionally.
منابع مشابه
Development of pulmonary blood flow evaluation method with a dynamic flat-panel detector: quantitative correlation analysis with findings on perfusion scan.
Pulmonary blood flow is reflected in dynamic chest radiographs as changes in X-ray translucency, i.e., pixel values. Thus, decreased blood flow should be observed as a reduction of the variation of X-ray translucency. We performed the present study to investigate the feasibility of pulmonary blood flow evaluation with a dynamic flat-panel detector (FPD). Sequential chest radiographs of 14 subje...
متن کامل[Pulmonary functional diagnostic imaging using a dynamic flat-panel detector: comparison with findings in pulmonary scintigraphy].
Pulmonary ventilation and circulation dynamics are reflected on dynamic chest radiographs as changes in X-ray translucency,i.e., pixel values. The present study was performed to develop a pulmonary functional evaluation method based on the changes in pixel value, and to investigate the clinical usefulness of our method. Sequential chest radiographs of 20 subjects (abnormal,n=12; normal,n=8) dur...
متن کامل[Reproducibility of dynamic chest radiography with a flat-panel detector - respiratory changes in pixel value].
Dynamic chest radiography using a flat panel detector (FPD) with a large field of view is expected to be a useful pulmonary functional evaluation method based on the respiratory changes in pixel value. For clinical use as a follow-up and therapeutic evaluation tool, the system must have a high degree of reproducibility in measurements of pixel values. The present study was performed to investig...
متن کاملDigital Radiography Using Flat Panel Detector for the Non-Destructive Evaluation of Space Vehicle Components
Digital technology has been introduced into radiography very recently but the conventional film based technique will be totally out of the arena in no time as what has happened in the photography field. The state-of-art technology is direct digital Xray imaging based on Flat Panel Detector technology in which the X-ray image is displayed on the computer without the intermediate optics or mechan...
متن کاملTitle Simulation approach for the evaluation of tracking accuracy inradiotherapy : A preliminary study
40 Real-time tumor tracking in external radiotherapy can be achieved by diagnostic (kV) X-ray 41 imaging with a dynamic flat-panel detector (FPD). It is important to keep the patient dose as 42 low as possible while maintaining tracking accuracy. Simulation approach would be helpful to 43 optimize the imaging conditions. This study was performed to develop a computer simulation 44 platform base...
متن کامل