Comparison of Depth of Cure, Hardness and Heat Generation of LED and High Intensity QTH Light Sources

نویسندگان

  • Sayed Mostafa Mousavinasab
  • Ian Meyers
چکیده

OBJECTIVES To compare curing performance of a second generation LED curing light with a high power tungsten quartz halogen (QTH). METHODS A hybrid composite resin (Filtek Z 250, 3M, USA) was used as test material and cured using a second generation LED light (Translux Power Blue™, Heraus Kulzer ,Germany) or a very high power QTH light unit (EMS, Switzerland). A two split aluminum mold was used to prepare ten samples with LED light source cured for forty seconds and ten samples prepared using high power QTH light unit, cured for four or six seconds recommended exposure time. Hardness, depth of cure (DOC) and thermal rise during exposure time by these light sources were measured. The data submitted to analysis of variance (ANOVA), Tukey's and student's t tests at 5% significance level. RESULTS Significant differences were found in hardness, DOC of samples cured by above mentioned light sources and also in thermal rises during exposure time. The curing performance of the tested QTH was not as well as the LED light. TPB light source produced the maximum hardness (81.25, 73.29, 65.49,55.83 and 24.53 for 0 mm, 1 mm, 2 mm, 3 mm and 4 mm intervals) and DOC (2.64 mm) values with forty seconds irradiation time and the high power (QTH) the least hardness (73.27, 61.51 and 31.59 for 0 mm, 1 mm and 2 mm, respectively) and DOC (2 mm) values with four seconds irradiation time. Thermal rises during 4 s and 6 s curing time using high power QTH and tested LED were 1.88°C, 3°C and 1.87°C, respectively. CONCLUSIONS The used high power LED light produced greater hardness and depth of cure during forty seconds exposure time compared to high power QTH light with four or six seconds curing time. Thermal rise during 6 s curing time with QTH was greater compared to thermal changes occurred during 40 s curing time with tested LED light source. There was no difference seen in thermal changes caused by LED light with 40 s and QTH light with 4 s exposure time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of Exposure Times and Light Curing Sources on Surface Micro-Hardness of a Resin Modified Glass Ionomer

Introduction: The aim of this study was to evaluate the influenceof different light curing systems and curing times on the micro-hardness of aresin modified glass ionomer. Methods: Forty two samples of ResinModified Glass Ionomer (RMGI) were prepared using stainless steel cylindrical mold(8 × 2 mm) and randomly divided into six groups of seven. Three groups werecured with a Quartz Tungsten Halo...

متن کامل

Curing Efficacy of Light Emitting Diodes of Dental Curing Units

BACKGROUND AND AIMS The aim of the present study was to compare the efficacy of quartz tungsten halogen (QTH) and light emitting diode (LED) curing lights on polymerization of resin composite. MATERIALS AND METHODS A hybrid resin composite was used to prepare samples which were cured using two QTH and ten LED light curing sources. Twelve groups, each containing ten samples, were prepared usin...

متن کامل

Evaluation of depth of cure and knoop hardness in a dental composite, photo-activated using different methods

The study aimed at evaluating the depth of cure and knoop hardness of a microfine-hybrid composite resin that was photo-activated using different methods. A bipartite brass mold was filled with composite resin and photo-activation was performed using four methods: (1) Intermittent method using quartz tungsten halogen (QTH) light curing unit (LCU) (2) Continuous method (QTH) (3) Exponential meth...

متن کامل

بررسی میزان پلیمریزاسیون یک رزین باندینگ آزمایشگاهی کیور شده باLED  توسط دستگاه DSC

Background and Aim: Extent of polymerization (Ep) is the rate at which methacrylate C=C bonds are converted to aliphatic C-C bonds. The higher the Ep value, the better the polymerization of the polymer. If the polymer dose not polymerize sufficiently, it could have destructive effects e.g. releasing monomer, initiator, free radical or insufficient polymerization of hybrid layer. Therefore, meas...

متن کامل

Effect of Light Curing Unit Characteristics on Light Intensity Output, Depth of Cure and Surface Micro-hardness of Dental Resin Composite.

BACKGROUND Modern dental composite restorations are wholly dependent on the use of Visible Light Curing devices. The characteristics of these devices may influence the quality of composite resin restorations. OBJECTIVE To determine the characteristics of light curing units (LCUs) in dental clinics in Nairobi and their effect on light intensity output, depth of cure (DOC) and surface micro-har...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011