An in vitro study comparing limited to full cementation of polyethylene glenoid components

نویسندگان

  • R. Andrew Glennie
  • Joshua W. Giles
  • James A. Johnson
  • George S. Athwal
  • Kenneth J. Faber
چکیده

BACKGROUND Glenoid component survival is critical to good long-term outcomes in total shoulder arthroplasty. Optimizing the fixation environment is paramount. The purpose of this study was to compare two glenoid cementing techniques for fixation in total shoulder arthroplasty. METHODS Sixteen cadaveric specimens were randomized to receive peg-only cementation (CPEG) or full back-side cementation (CBACK). Physiological cyclic loading was performed and implant displacement was recorded using an optical tracking system. The cement mantle was examined with micro-computed tomography before and after cyclic loading. RESULTS Significantly greater implant displacement away from the inferior portion of the glenoid was observed in the peg cementation group when compared to the fully cemented group during the physiological loading. The displacement was greatest at the beginning of the loading protocol and persisted at a diminished rate during the remainder of the loading protocol. Micro-CT scanning demonstrated that the cement mantle remained intact in both groups and that three specimens in the CBACK group demonstrated microfracturing in one area only. DISCUSSION Displacement of the CPEG implants away from the inferior subchondral bone may represent a suboptimal condition for long-term implant survival. Cement around the back of the implant is suggested to improve initial stability of all polyethylene glenoid implants. CLINICAL RELEVANCE Full cementation provides greater implant stability when compared to limited cementation techniques for insertion of glenoid implants. Loading characteristics are more favorable when cement is placed along the entire back of the implant contacting the subchondral bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Evaluation of All-Polyethylene Pegged Bony Ingrowth Glenoid Fixation Techniques on Implant Micromotion.

Newer glenoid components that allow for hybrid cement fixation via traditional cementation of peripheral pegs and bony ingrowth into an interference-fit central peg introduce the possibility of long-term biological fixation. However, little biomechanical work has been done on the initial stability of these components and the various fixation options. We conducted a study in which all-polyethyle...

متن کامل

Influence of peg design and cement mantle thickness on pull-out strength of glenoid component pegs.

Fixation of the glenoid component is critical to the outcome of total shoulder arthroplasty. In an in vitro study, we analysed the effect of surface design and thickness of the cement mantle on the pull-out strength of the polyethylene pegs which are considered essential for fixation of cemented glenoid components. The macrostructure and surface of the pegs and the thickness of the cement mantl...

متن کامل

Observations on retrieved glenoid components from total shoulder arthroplasty.

HYPOTHESIS Polyethylene components retrieved at revision of total knee and hip replacements have been analyzed to study the effect of design, patient, and surgical factors on initial implant performance, but few studies have reported similar types of findings in retrieved glenoids. MATERIALS AND METHODS From 1979 to 2006, 78 glenoid components were retrieved from revision surgery in 73 patien...

متن کامل

Comparison of conforming and nonconforming retrieved glenoid components.

The purpose of this study was to compare differences in wear performance of conforming and nonconforming glenoid designs, using clinical, radiographic, and retrieved polyethylene glenoid component outcome Sixty-three glenoids met the study criteria, and each glenoid was assigned to the conforming group (if the radii of curvature of the humeral and glenoid components were identical) or the nonco...

متن کامل

Incidence of early development of radiolucent lines in keeled polyethylene glenoid components after total shoulder arthroplasty.

Glenoid loosening after total shoulder arthroplasty (TSA) remains a major concern. The purpose of this study was to determine the incidence of radiolucent lines (RLLs) after TSA performed with modern glenoid bone preparation and cement techniques for keeled-back glenoid components. One hundred ten consecutive patients with osteoarthritis were included in this study. Patients had undergone prima...

متن کامل