[Determination of a Friction Coefficient for THA Bearing Couples].

نویسندگان

  • M Vrbka
  • D Nečas
  • J Bartošík
  • M Hartl
  • I Křupka
  • A Galandáková
  • J Gallo
چکیده

PURPOSE OF THE STUDY The wear of articular surfaces is considered one of the most important factors limiting the life of total hip arthroplasty (THA). It is assumed that the particles released from the surface of a softer material induce a complex inflammatory response, which will eventually result in osteolysis and aseptic loosening. Implant wear is related to a friction coefficient which depends on combination of the materials used, roughness of the articulating surfaces, internal clearance, and dimensions of the prosthesis. MATERIAL AND METHODS The selected parameters of the bearing couples tested were studied using an experimental device based on the principle of a pendulum. Bovine serum was used as a lubricant and the load corresponded to a human body mass of 75 kg. The friction coefficient was derived from a curve of slowdown of pendulum oscillations. Roughness was measured with a device working on the principle of interferometry. Clearance was assessed by measuring diameters of the acetabular and femoral heads with a 3D optical scanner. The specimens tested included unused metal-on-highly cross-linked polyethylene, ceramic-on-highly cross-linked polyethylene and ceramic-on-ceramic bearing couples with the diameters of 28 mm and 36 mm. For each measured parameter, an arithmetic mean was calculated from 10 measurements. RESULTS 1) The roughness of polyethylene surfaces was higher by about one order of magnitude than the roughness of metal and ceramic components. The Protasul metal head had the least rough surface (0.003 μm). 2) The ceramic-on-ceramic couples had the lowest clearance. Bearing couples with polyethylene acetabular liners had markedly higher clearances ranging from 150 μm to 545 μm. A clearance increased with large femoral heads (up to 4-fold in one of the couple tested). 3) The friction coefficient was related to the combination of materials; it was lowest in ceramic-on-ceramic surfaces (0.11 to 0.12) and then in ceramic-on-polyethylene implants (0.13 to 0.14). The friction coefficient is supposed to increase with a decreasing femoral head diameter. However, in the bearing couples with polyethylene liners manufactured by one company, paradoxically, the friction coefficient slightly increased with an increase in femoral head size from 28 mm to 36 mm. 4) The lowest friction moment (< 3.5 Nm) was found for ceramic-on-ceramic implants 28 mm in diameter; the highest values were recorded in metal-on-polyethylene bearing couples 36 mm in diameter (> 7 Nm). DISCUSSION Although our study confirmed that the bearing couples produced by different manufacturers varied to some extent in the parameters studied, in our opinion, this variability was not significant because it was not within an order of magnitude in any of the tests. CONCLUSIONS The study showed that both the friction coefficient and the friction moment are affected more by the combination of materials than by the diameter of a femoral head. The best results were achieved in ceramic-on-ceramic implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of the Tribological Behavior of a Pin on Disc Type of Contact

The present work aims at contributing to the study of the complex phenomenon of wear of pin on disc contact in dry sliding friction between two material couples (bronze/steel and unsaturated polyester virgin and charged with graphite powder/steel). The work consists of the determination of the coefficient of friction, the study of the influence of the tribological parameters on this coefficient...

متن کامل

Aging effect on the tribological behavior of a Novel 3Y-TZP/Nb Biocomposite against Ultra High Molecular Weight Polyethylene (UHMWPE)

The aim of this study was to evaluate the friction and wear behavior of ultra high molecular weight polyethylene (UHMWPE) against 3Y-TZP and a novel 3Y-TZP/niobium (Nb) biocomposite. The ceramic and the biocomposite materials were subjected to an accelerated aging process to evaluate the changes in the tribological behavior after this treatment. To carry out the tribological tests, a reciprocat...

متن کامل

Performance Evaluation of Nano-Lubricants at Thrust Slide-Bearing of Scroll Compressors

This paper presents the friction and anti-wear characteristics of nano-oil with a mixture of refrigerant oil and carbon nano-particles in the thrust slide-bearing of scroll compressors. Frictional loss in the thrust slide-bearing occupies a large part of total mechanical loss in scroll compressors. The characteristics of friction and anti-wear using nano-oil is evaluated using a thrust bearing ...

متن کامل

Mechanical Loss Reduction at Thrust Bearings of Scroll Compressors Using R407C

This paper presents the experimental research into high mechanical efficiency at thrust bearings of low-side scroll compressors for air conditioners with the new refrigerant R407C and Polyolester (POE) lubricant. In order to examine the friction loss at the thrust bearing under a test condition which is close to the actual running condition of compressors, the authors developed a friction test ...

متن کامل

Effective of Main Bearing Bolt Manufacturing Parameters on Functional Performance in High Speed Diesel Engine using Torque-Angle Method

In marine diesel engine, main bearing bolts (M18×1.5) withstand large tensile and cyclic loads to keep the crank shaft, bearing whit acceptable clearance and precision clamping force at high crank speed like 3100 rpm. In this research, the relationship between torque and clamp force, the friction coefficient, the effect of number of tightening and bearing conditions on the new manufactured bolt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca

دوره 82 5  شماره 

صفحات  -

تاریخ انتشار 2015