Mechanical testing of impaction bone grafting in the tibia: initial stability and design of the stem.

نویسندگان

  • A D Toms
  • D McClelland
  • L Chua
  • M de Waal Malefijt
  • N Verdonschot
  • R Spencer Jones
  • J-H Kuiper
چکیده

Clinical experience of impaction bone grafting for revision knee arthroplasty is limited, with initial stability of the tibial tray emerging as a major concern. The length of the stem and its diameter have been altered to improve stability. Our aim was to investigate the effect of the type of stem, support of the rim and graft impaction on early stability of the tray. We developed a system for impaction grafting of trays which we used with morsellised bone in artificial tibiae. Trays with short, long thick or long thin stems were implanted, with or without support of the rim. They were cyclically loaded while measuring relative movement. Long-stemmed trays migrated 4.5 times less than short-stemmed trays, regardless of diameter. Those with support migrated 2.8 times less than those without. The migration of short-stemmed trays correlated inversely with the density of the impacted groups. That of impaction-grafted tibial trays was in the range reported for uncemented primary trays. Movements of short-stemmed trays without cortical support were largest and sensitive to the degree of compaction of the graft. If support of the rim was sufficient or a long stem was used, impacted morsellised bone graft achieved adequate initial stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Biomechanical Analysis

J Bone Joint Surg [Br] 2009;91-B:271-7. Received 16 June 2008; Accepted after revision 26 September 2008 The treatment of bony defects of the tibia at the time of revision total knee replacement is controversial. The place of compacted morsellised bone graft is becoming established, particularly in contained defects. It has previously been shown that the initial stability of impaction-grafted t...

متن کامل

Reconstruction of femoral defects in revision hip surgery: risk of fracture and stem migration after impaction bone grafting.

The use of impaction bone grafting during revision arthroplasty of the hip in the presence of cortical defects has a high risk of post-operative fracture. Our laboratory study addressed the effect of extramedullary augmentation and length of femoral stem on the initial stability of the prosthesis and the risk of fracture. Cortical defects in plastic femora were repaired using either surgical me...

متن کامل

In-vitro Prediction of Cemented and Non-cemented Revision Stem Stability in Impaction Bone Grafting

BONE GRAFTING +*Mak, S Y; *Smith, S D; *Miles, A W +*Centre for Orthopaedic Biomechanics, University of Bath, UK [email protected] INTRODUCTION: Impaction bone grafting (IBG) has been used in revision hip replacement for more than 15 years. The objective is to impact allograft bone chips into the medullary canal to compensate for bone stock loss after failed primary hip replacement. Initial st...

متن کامل

Larger bone graft size and washing of bone grafts prior to impaction enhances the initial stability of cemented cups: experiments using a synthetic acetabular model.

BACKGROUND Bone defects after failed total hip arthroplasty can be reconstructed with impacted morselized bone grafts and a cemented cup. On the acetabular side, the effects on initial cup stability of washing bone grafts prior to impaction and bone graft size remain unclear. Related to these variables, cement penetration and inter-particle shear resistance have been suggested to be critical fa...

متن کامل

Impaction bone grafting for tibial defects in knee replacement surgery. Results at two years.

Bone loss with large defects poses a complex and challenging problem in primary and revision knee arthroplasty. The defects are often irregular and difficult to quantify. One of the techniques available to restore bone in such cases is Knee Impaction Bone Grafting (KIBG); however, the clinical literature to support this technique is weak. Since 2006 we have used impaction bone grafting for cont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 87 5  شماره 

صفحات  -

تاریخ انتشار 2005