Global and regional evaluation of systolic and diastolic left ventricular temporal parameters using a novel program for ECG-gated myocardial perfusion SPECT--validation by comparison with gated equilibrium radionuclide angiography and speckle-tracking radial strain from echocardiography.
نویسندگان
چکیده
BACKGROUND A newly developed program, named cardioGRAF, enabled the evaluation of left ventricular (LV) systolic and diastolic temporal parameters for the estimation of heart failure using ECG-gated myocardial perfusion SPECT (GMPS). OBJECTIVE The feasibility of those global (g-) and regional (r-) parameters was validated to compare with gated equilibrium radionuclide angiography (ERNA) and speckle-tracking radial strain (STS) from echocardiography. METHODS Thirty-three patients were studied using GMPS and ERNA (n=11) or GMPS and STS (n=22). The following g- or r-parameters obtained by cardioGRAF and ERNA or STS were compared: time to end systole (TES), time from end systole to peak filling rate (TPF1), time from 0 to peak filling rate (TPF2), time to peak radial strain (TPS), time from peak strain to peak negative strain rate (TP-SR1), and time from 0 to peak negative strain rate (TP-SR2). RESULTS All g-parameters were successfully obtained by cardioGRAF and ERNA. The results demonstrated good correlations (g-TES: r = 0.79, p < 0.005; g-TPF1: r = 0.75, p < 0.02; TPF2: r = 0.83, p < 0.005). The differences were 11.9 +/- 31.8 ms in g-TES, 19.9 +/- 65.4 ms in g-TPF1, and 37.7 +/- 67.4 ms in g-TPF2. All r-parameters were successfully obtained by cardioGRAF. Eight patients and 12 segments were excluded because of the inadequate quality of routine echocardiography for STS analysis. However, r-parameters obtained by cardioGRAF were significantly correlated with those of STS (r-TES and r-TPS: r = 0.61, p = 1 x 10(-8); r-TPF1 and r-TP-SR1: r = 0.69, p = 3 x 10(-11); r-TPF2 and r-TP-SR2: r = 0.76, p = 2 x 10(-15)). The differences were 22.1 +/- 38.2 ms between r-TES and r-TPS, 7.0 +/- 123.4 ms between r-TPF1 and r-TP-SR1, and 38.1 +/- 111.5 ms between r-TPF2 and r-TP-SR2. CONCLUSION The feasibility of evaluating systolic and diastolic temporal parameters by a new program was validated. This program has the potential to evaluate both diastolic and systolic heterogeneous wall motions which express dyssynchrony in heart failure.
منابع مشابه
Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملThe role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method
Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...
متن کاملDetermination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software
Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...
متن کاملNormal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT
Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...
متن کاملDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 21 2 شماره
صفحات -
تاریخ انتشار 2007