Improved determination of serum theophylline by gas chromatography with use of a nitrogen-phosphorus detector.
نویسندگان
چکیده
We describe a method for the 7-min determination of theophylline in less than 100 muL of serum. The procedure requires no centrifugation or solvent evaporation after extraction. Butylation is done on the gas-chromatographic column by injecting the serum extract followed by a butylating mixture which contains 1-iodobutane as the alkylating agent. The method is precise, accurate, and free of interference. Results correlate well with those by ultraviolet spectrophotometry.
منابع مشابه
Gas-chromatographic micro-scale procedure for theophylline, with use of a nitrogen-sensitive detector.
We report a micro-scale procedure for determination of theophylline by use of gas chromatography with nitrogen-sensitive detection. The procedure requires only 10 mul of serum, plasma, or saliva. This sample size makes the determination especially appropriate for monitoring in a pediatric population. With the sample volume used, background interference is equivalent to about 0.1 mg/liter and 0....
متن کاملDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study
Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...
متن کاملScreening and quantification of hypnotic sedatives in serum by capillary gas chromatography with a nitrogen-phosphorus detector, and confirmation by capillary gas chromatography-mass spectrometry.
We describe a quantitative screen for hypnotic-sedative drugs in which we use capillary gas chromatography with a nitrogen-phosphorus detector (GC/NPD) as the primary method and capillary gas chromatography-mass spectrometry (GC-MS) for confirmation. GC retention times of the acid-extracted underivatized drugs were stable (CVs less than 1%), and the detector response varied linearly over a 20-f...
متن کاملDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study
Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...
متن کاملPossibilities and problems with identification and determination of "new" hypnotics.
Authors discuss problems with identification and determination of flunitrazepam and zolpidem in biological material (BM). Over the recent years, these two structurally different substances have become the most frequently used as well as abused hypnotic drugs. This study presents applicability of immunochemical methods in the screening of flunitrazepam, one of the most commonly prescribed drugs ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 1 شماره
صفحات -
تاریخ انتشار 1979