Functional outcomes following locking plate fixation of complex proximal humeral fractures.

نویسندگان

  • Tingjun Ye
  • Lei Wang
  • Chengyu Zhuang
  • Yazi Wang
  • Weibin Zhang
  • Shijing Qiu
چکیده

The purpose of this study was to evaluate the functional outcome of patients with complex proximal humeral fractures fixated by locking plate technology. Eighty-nine patients (27 men, 62 women) older than 50 years with 3- and 4-part proximal humeral fractures were treated using locking plate fixation and followed up for more than 1 year. Functional outcomes were assessed by using the Disabilities of the Arm, Shoulder, and Hand (DASH) and Constant scores, and the complications were evaluated through physical and radiographic examinations. Mean DASH and Constant scores for all 89 patients were 19.6 and 66.6 points, respectively. No significant differences existed in the 2 scores between patients with 3- and 4-part fractures. Of the 71 patients without complications, 68 had an excellent functional outcome according to the DASH score, whereas 2 patients had an excellent outcome on the Constant score. For the 18 patients with complications, the functional outcomes were significantly poorer compared with patients without complications. According to the Constant score, all patients with complications were classified into a moderate or poor functional outcome, but the rate was 12% with the DASH score. In patients with 3- and 4-part proximal humeral fractures fixed with locking plate fixation, complications were the major cause of compromised functional outcomes. Based on these results, different conclusions would be reached when the functional outcome was assessed by using the DASH and Constant scores separately. Because the clinician-based Constant score may bias the results, patient-based assessments, such as the DASH score, are required for the evaluation of functional outcome after shoulder surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

Internal fixation with locking plate of 3- and 4-part proximal humeral fractures in elderly patients: complications and functional outcome.

Despite recent advances in operative techniques, internal fixation of (3- and 4-part) displaced proximal humeral fractures in elderly patients with osteoporotic bone remains controversial, sometimes followed by poor results. The aim of the present study was to evaluate outcomes of internal fixation with locking plate of multi-fragment proximal humeral fractures in elderly patients. The study co...

متن کامل

Efficacy comparison of intramedullary nails, locking plates and conservative treatment for displaced proximal humeral fractures in the elderly

Purpose The incidence of proximal humeral fractures is high in the elderly, and the superior management of these fractures remains a controversy. The study aims to compare clinical outcomes of intramedullary nails, locking plates and conservative treatment for the management of displaced proximal humeral fractures in the elderly. Patients and methods In this prospective study, a total of 198 ...

متن کامل

Locking plate fixation for proximal humerus fractures.

Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for p...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 2013