MRI for the assessment of malignancy in BI-RADS 4 mammographic microcalcifications
نویسندگان
چکیده
PURPOSE Assess the performance of breast MRI to diagnose breast cancer in BI-RADS 4 microcalcifications detected by mammography. MATERIALS AND METHODS This retrospective, IRB-approved study included 248 consecutive contrast-enhanced breast MRI (1.5T, protocol in accordance with EUSOBI recommendations) performed to further diagnose BI-RADS 4 microcalcifications detected at mammography during a 3-year period. Standard of reference had to be established by histopathology. Routine consensus reading results by two radiologists were dichotomized as positive or negative and compared with the reference standard (benign vs malignant) to calculate diagnostic parameters. RESULTS There were 107 malignant and 141 benign microcalcifications. Malignancy rates were 18.3% (23/126 BI-RADS 4a), 41.7% (25/60 BI-RADS 4b) and 95% (59/62 BI-RADS 4c). There were 103 true-positive, 116 true-negative, 25 false-positive, and 4 false-negative (one invasive cancer, three DCIS; 2 BI-RADS 4c, 1 BI-RADS 4b on mammography) breast MRI findings, effecting a sensitivity, specificity, PPV, and NPV of 96.3% (95%-CI 90.7-99.0%), 82.3% (95%-CI 75.0-88.2%), 80.5% (95%-CI 72.5-87.0%) and 96.7% (95%-CI 91.7-99.1%), respectively. CONCLUSION MRI is an accurate tool to further diagnose BI-RADS 4a and 4b microcalcifications and may be helpful to avoid unnecessary biopsies in BI-RADS 4a and 4b lesions. BI-RADS 4c microcalcifications should be biopsied irrespective of MRI findings.
منابع مشابه
A Comparative Study of the Diagnostic Value of Contrast-Enhanced Breast MR Imaging and Mammography on Patients with BI-RADS 3–5 Microcalcifications
OBJECTIVE To retrospectively investigate the diagnostic value of breast MRI in patients with BI-RADS 3-5 microcalcifications in mammography. METHODS Eighty-four patients with BI-RADS 3-5 microcalcifications on mammography underwent breast MR exams before surgical biopsy with a hookwire position under mammographic guidance. Two radiologists reviewed each lesion with BI-RADS by consensus. The d...
متن کاملBreast magnetic resonance imaging as a problem-solving modality in mammographic BI-RADS 3 lesions
The probability of a mammographic Breast Imaging Reporting and Data System (BI-RADS) 3 lesion being cancer is considered to be less than 2%. Therefore, the work-up of a mammographic BI-RADS 3 lesion should be biopsy or follow-up mammography after 6 months. However, most patients referred for biopsy have benign disease. Although the negative predictive value (NPV) of magnetic resonance imaging (...
متن کاملEvaluation of the Role of Dynamic Contrast-Enhanced MR Imaging for Patients with BI-RADS 3–4 Microcalcifications
OBJECTIVE The purpose of study was to prospectively evaluate the diagnostic performance of dynamic contrast-enhanced MR imaging in the differentiation of malignant lesions from benign ones in patients with BI-RADS 3-4 microcalcifications detected by mammography. MATERIALS AND METHODS 93 women with 100 microcalcifications had undergone breast MRI from June 2010 to July 2013. Subsequently, 91 r...
متن کاملRadiological and Histological Correlation of Non-palpable Breast Lesions in Patients Submitted to Preoperative Marking According to Bi-rads Classification*
OBJECTIVE: To evaluate the positive predictive value for BI-RADS (Breast Imaging Reporting and Data System) categories 3, 4 and 5, correlating mammographic and histological diagnosis in non-palpable breast lesions. MATERIALS AND METHODS: Analytical-descriptive study of 169 women submitted to stereotactic localization for surgical biopsy of non-palpable breast lesions. Mammographic and histologi...
متن کاملThe positive predictive value of BI-RADS microcalcification descriptors and final assessment categories.
OBJECTIVE The purpose of this article is to retrospectively assess the likelihood of malignancy of microcalcifications according to the BI-RADS descriptors in a digital mammography environment. MATERIALS AND METHODS The study included 146 women with calcifications who underwent imaging-guided biopsy between April 2005 and July 2006. Digital mammograms procured before biopsy were analyzed inde...
متن کامل