Micro-volume couette flow sample orientation for absorbance and fluorescence linear dichroism.
نویسندگان
چکیده
Linear dichroism (LD) can be used to study the alignment of absorbing chromophores within long molecules. In particular, Couette flow LD has been used to good effect in probing ligand binding to DNA and to fibrous proteins. This technique has been previously limited by large sample requirements. Here we report the design and application of a new micro-volume Couette flow cell that significantly enhances the potential applications of flow LD spectroscopy by reducing the sample requirements for flow linear dichroism to 25 microL (with concentrations such that the absorbance maximum of the sample in a 1-cm pathlength cuvette is approximately 1). The micro-volume Couette cell has also enabled the measurement of fluorescence-detected Couette flow linear dichroism. This new technique enables the orientation of fluorescent ligands to be probed even when their electronic transitions overlap with those of the macromolecule and conversely. The potential of flow-oriented fluorescence dichroism and application of the micro-volume Couette LD cell are illustrated by the collection of data for DNA with minor groove and intercalating ligands: DAPI, Hoechst, and ethidium bromide. As with conventional fluorescence, improved sensitivity compared with absorbance LD is to be expected after instrumentation optimization.
منابع مشابه
Breaking the 200 nm limit for routine flow linear dichroism measurements using UV synchrotron radiation.
The first synchrotron radiation flow linear dichroism spectra are reported. High-quality spectral data can be collected from 450 nm down to 180 nm in contrast to the practical cutoff of approximately 200 nm on benchtop instruments. State-of-the-art microvolume capillary Couette flow linear dichroism was successfully ported to a synchrotron radiation source. The sample volume required is < 50 mi...
متن کاملProtein fiber linear dichroism for structure determination and kinetics in a low-volume, low-wavelength couette flow cell.
High-resolution structure determination of soluble globular proteins relies heavily on x-ray crystallography techniques. Such an approach is often ineffective for investigations into the structure of fibrous proteins as these proteins generally do not crystallize. Thus investigations into fibrous protein structure have relied on less direct methods such as x-ray fiber diffraction and circular d...
متن کاملVarying flow in linear dichroism cells
The usefulness of linear dichroism (LD) in structure identification depends strongly on the orientation of the molecule in the linear dichroism cell. Hence, the fluid flow inside the linear dichroism cell which performs this act of orientation is of great importance. As such, this paper records the steps taken to identify the varying flow states in the cell, with changing rotation speed, and th...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biophysical journal
دوره 87 3 شماره
صفحات -
تاریخ انتشار 2004