Radiation Dose from Whole-Body F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Nationwide Survey in Korea
نویسندگان
چکیده
The purpose of this study was to estimate average radiation exposure from (18)F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) examinations and to analyze possible factors affecting the radiation dose. A nation-wide questionnaire survey was conducted involving all institutions that operate PET/CT scanners in Korea. From the response, radiation doses from injected FDG and CT examination were calculated. A total of 105 PET/CT scanners in 73 institutions were included in the analysis (response rate of 62.4%). The average FDG injected activity was 310 ± 77 MBq and 5.11 ± 1.19 MBq/kg. The average effective dose from FDG was estimated to be 5.89 ± 1.46 mSv. The average CT dose index and dose-length product were 4.60 ± 2.47 mGy and 429.2 ± 227.6 mGy∙cm, which corresponded to 6.26 ± 3.06 mSv. The radiation doses from FDG and CT were significantly lower in case of newer scanners than older ones (P < 0.001). Advanced PET technologies such as time-of-flight acquisition and point-spread function recovery were also related to low radiation dose (P < 0.001). In conclusion, the average radiation dose from FDG PET/CT is estimated to be 12.2 mSv. The radiation dose from FDG PET/CT is reduced with more recent scanners equipped with image-enhancing algorithms.
منابع مشابه
Cumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients
Background: Breast cancer is a common disease in radiation oncology. We evaluated the radiation dose received by breast cancer patients, an often-neglected concern. Materials and Methods: The total effective radiation dose in 101 breast cancer patients was calculated by summing the effective doses of individual diagnostic imaging tests from the first hospital visit to the initiation of radiothe...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملInflammatory Pseudotumor in the Epidural Space of the Lumbosacral Spine on F-18 FDG PET/CT
An inflammatory pseudotumor (IPT) is a rare benign lesion, characterized by nonneoplastic proliferation of inflammatory cells and presence of intermingling collagen fibers. IPT commonly occurs in the lungs and orbita, while an intraspinal IPT is extremely rare. IPT can mimic both clinically and radiologically malignant processes, and making a definitive preoperative diagnosis is often difficult...
متن کاملLung nodule detected by F-18 fluorodeoxyglucose positron emission tomography-computed tomography in patients with papillary thyroid cancer, negative 131I whole body scan, and undetectable serum-stimulated thyroglobulin levels: two case reports
UNLABELLED INTRODUCTION When a pulmonary nodular lesion is detected by F-18 fluorodeoxyglucose positron emission tomography-computed tomography in a patient with post-surgical papillary thyroid carcinoma with undetectable serum-stimulated thyroglobulin levels and negative 131I whole body scan, diagnosis and management of the nodule may be confusing. CASE PRESENTATION We describe two post-s...
متن کاملNuclear medicine imaging in bone metastases
Nuclear medicine techniques designed to identify bone metastases are reviewed. They include planar and whole body, single photon emission tomography (SPET), F-18 Fluorine and FDG, deoxyglucose, positron emission tomography (PET), bone imaging.
متن کامل