Lumped Element Electrical Model based on Three Resistors for Electrical Impedance in Radiofrequency Cardiac Ablation: Estimations from Analytical Calculations and Clinical Data
نویسندگان
چکیده
The electrical impedance measured during radiofrequency cardiac ablation (RFCA) is widely used in clinical studies to predict the heating evolution and hence the success of the procedure. We hypothesized that a model based on three resistors in series can mimic the total electrical impedance measured during RFCA. The three resistors or impedances are given by: impedance associated with the tissue around the active electrode (myocardium and circulating blood) (Z-A), that associated with the tissue around the dispersive electrode (Z-DE) and that associated with the rest of the body (Z-B). Our objective was to quantify the values associated with these three impedance types by an analytical method, after which the values obtained would be compared to those estimated from clinical data from previous studies. The results suggest that an RFCA using a 7 Fr 4-mm electrode would give a Z-A of around 75 ohms, a Z-DE around 20 ohms, and Z-B would be 15±10 ohms (for body surface area variations between 1.5 and 2.5 m^2). Finally, adaptations of the proposed model were used to explain the results of previous clinical studies using a different electrode arrangement, such as in bipolar ablation of the ventricular septum.
منابع مشابه
Impedance measurement to assess epicardial fat prior to RF intraoperative cardiac ablation: a feasibility study using a computer model.
Radiofrequency (RF) cardiac ablation is used to treat certain types of arrhythmias. In the epicardial approach, efficacy of RF ablation is uncertain due to the presence of epicardial adipose tissue interposed between the ablation electrode and the atrial wall. We planned a feasibility study based on a theoretical model in order to assess a new technique to estimate the quantity of fat by conduc...
متن کاملEquivalent Circuit Model for Square Ring Slot Frequency Selective Surface
An equivalent circuit model for predicting the frequency response of a square ring slot frequency selective surface (SRS-FSS) for normal incidence is described. The proposed FSS consists of an array of square patches centered within a wire grid. The presented circuit model is formed by the impedance of the wire grid that is parallel with the impedance of the patch array, also the mutual couplin...
متن کاملExperiment and Simulation Validated Analytical Equivalent Circuit Model for Piezoelectric Micro-Machined Ultrasonic Transducer
An analytical Mason equivalent circuit is derived for a circular, clamped plate piezoelectric micro-machined ultrasonic transducer (pMUT) design in 31 mode considering an arbitrary electrode configuration at any axisymmetric vibration mode. The explicit definition of lumped parameters based entirely on geometry, material properties and defined constants enables straightforward and wide ranging ...
متن کاملImpedance During Radiofrequency Ablation of Ventricular Myocardium
The purpose of this study was to correlate changes in electrical impedance with the electrode-tissue interface temperature and to characterize the associated events occurring at the catheter tip electrode. In a canine model, lesions were created in vitro (n =49) and in vivo (n =31) and radiofrequency power settings were varied. Electrode-tissue interface temperature, delivered current, and volt...
متن کاملAnterior-posterior impedance cardiography: a new approach to accurate, non-invasive monitoring of cardiac function.
The conventional impedance cardiogram is a record of pulsatile changes in the electrical impedance of the chest with each heartbeat. The signal seems intuitively related to cardiac stroke volume. However doubts persist about the validity of stroke volume measurements based on electrical impedance. This paper presents a new electrical axis for impedance cardiography that is perpendicular to the ...
متن کامل