Influence of background size, luminance and eccentricity on different adaptation mechanisms
نویسندگان
چکیده
Mechanisms of light adaptation have been traditionally explained with reference to psychophysical experimentation. However, the neural substrata involved in those mechanisms remain to be elucidated. Our study analyzed links between psychophysical measurements and retinal physiological evidence with consideration for the phenomena of rod-cone interactions, photon noise, and spatial summation. Threshold test luminances were obtained with steady background fields at mesopic and photopic light levels (i.e., 0.06-110cd/m(2)) for retinal eccentricities from 0° to 15° using three combinations of background/test field sizes (i.e., 10°/2°, 10°/0.45°, and 1°/0.45°). A two-channel Maxwellian view optical system was employed to eliminate pupil effects on the measured thresholds. A model based on visual mechanisms that were described in the literature was optimized to fit the measured luminance thresholds in all experimental conditions. Our results can be described by a combination of visual mechanisms. We determined how spatial summation changed with eccentricity and how subtractive adaptation changed with eccentricity and background field size. According to our model, photon noise plays a significant role to explain contrast detection thresholds measured with the 1/0.45° background/test size combination at mesopic luminances and at off-axis eccentricities. In these conditions, our data reflect the presence of rod-cone interaction for eccentricities between 6° and 9° and luminances between 0.6 and 5cd/m(2). In spite of the increasing noise effects with eccentricity, results also show that the visual system tends to maintain a constant signal-to-noise ratio in the off-axis detection task over the whole mesopic range.
منابع مشابه
Effect of eccentricity on luminance-pedestal flicker thresholds
We investigated the effect that spatially coincident luminance increments (luminance pedestals) have on flicker thresholds at several eccentricities and target sizes. Luminance pedestals elevated flicker amplitude-thresholds more when stimuli were presented eccentrically, both at low (4 Hz) and high (20 Hz) temporal frequencies. Altering the size of the eccentric stimulus failed to equate centr...
متن کاملMesopic luminance assessed with minimum motion photometry.
We measured the relative contribution of rods and cones to luminance across a range of photopic, mesopic, and scotopic adaptation levels and at various retinal eccentricities. We isolated the luminance channel by setting motion-based luminance nulls (minimum motion photometry) using annular stimuli. Luminance nulls between differently colored stimuli require equality in a weighted sum of rod an...
متن کاملWhy do shape aftereffects increase with eccentricity?
Studies have shown that spatial aftereffects increase with eccentricity. Here, we demonstrate that the shape-frequency and shape-amplitude aftereffects, which describe the perceived shifts in the shape of a sinusoidal-shaped contour following adaptation to a slightly different sinusoidal-shaped contour, also increase with eccentricity. Why does this happen? We first demonstrate that the percept...
متن کاملMechanisms mediating visual detection in static perimetry.
PURPOSE The usual stimuli in static perimetry are white-light luminance increments. However, the specific visual detection mechanisms involved in perimetry are unknown because all classes of neural mechanisms are sensitive to spectrally broadband stimuli. The objective of this study was to determine the relative sensitivities of nonopponent and opponent detecting mechanisms under standard perim...
متن کاملReaction time in automated kinetic perimetry: effects of stimulus luminance, eccentricity, and movement direction
PURPOSE To determine the effects of stimulus eccentricity and luminance level on the reaction time (RT) of young normal volunteers during automated kinetic campimetry. METHODS We used a specially designed video-campimetric device equipped with a continuous infrared (IR) pupillographic fixation control (Tübingen Computer Campimeter) and recorded reaction times upon presenting horizontally movi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 125 شماره
صفحات -
تاریخ انتشار 2016