Effects of prosthetic foot forefoot flexibility on gait of unilateral transtibial prosthesis users.

نویسندگان

  • Elizabeth Klodd
  • Andrew Hansen
  • Stefania Fatone
  • Mark Edwards
چکیده

Five solid-ankle experimental prosthetic feet were used in this double-blind randomized crossover study to determine the effects of forefoot flexibility on gait of 14 unilateral transtibial prosthesis users. Flexibility in experimental feet was altered by changing the number of flexural hinges in their forefoot sections. When experimental prosthetic foot conditions were compared, measured prosthetic ankle dorsiflexion range of motion increased as much as 3.3° with increasing flexibility (p < 0.001) and the foot's anterior moment arm (measured as the effective foot length ratio) increased as much as 23% of the foot length with decreasing flexibility (p < 0.001). Subjects also showed increases in the difference between sound and prosthetic ankle moments as high as 0.53 Nm/kg in late stance phase of walking as flexibility decreased (p < 0.001). The difference between first peaks of the vertical ground reaction forces on the sound and prosthetic sides increased as much as 9% of body weight when subjects used the foot with the greatest flexibility (p = 0.001). The results of this study suggest solid-ankle prosthetic foot designs with overly flexible forefoot sections can cause a "drop-off" effect in late stance phase and during the transition of loading between prosthetic and contralateral limbs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of prosthetic foot forefoot flexibility on oxygen cost and subjective preference rankings of unilateral transtibial prosthesis users.

The investigators conducted a double-blind randomized crossover study to determine the effects of prosthetic foot forefoot flexibility on oxygen cost and subjective preference rankings of 13 unilateral transtibial prosthesis users. Five experimental feet were fabricated for use in the study: F1, F2, F3, F4, and F5. F1 was most flexible, F5 was least flexible, and F3 was designed to conform to a...

متن کامل

Effects of a flat prosthetic foot rocker section on balance and mobility.

Previous studies have shown that the effective rocker shape of the physiologic ankle-foot system during standing and fore-aft swaying is much flatter than that used during walking, which indicates a more stable base of support for the standing/swaying activity. Previous work suggests that flat regions within the effective rocker shapes of prosthetic ankle-foot systems could provide enhanced sta...

متن کامل

Effect of an 8-Weeks of Comprehensive Corrective Protocol on Postural control, low Back Pain, Gait Speed and Quality of Life on Unilateral Transtibial Amputees

Aims: Amputation makes a person susceptible to postural deviation and compensatory movements and causes reduced performance, biocompatibility, pain, and dissatisfaction. The purpose of this study was to investigate the effect of eight weeks of a comprehensive rehabilitation protocol on indicators of postural control, back pain, quality of life, and gait speed in adults with unilateral lower lim...

متن کامل

JRRD at a Glance Effect of prosthetic ankle units on roll-over shape characteristics during walking in persons with bilateral transtibial amputations

Some functions of walking are adversely affected in prosthesis users because of reduced or absent ankle motion. However, combining a prosthetic ankle unit with a particular prosthetic foot could have unanticipated consequences. This study investigated the effect of prosthetic ankle units on the gait of persons with bilateral transtibial amputations. Subjects were tested while walking with and w...

متن کامل

The effects of prosthetic ankle stiffness on stability of gait in people with transtibial amputation.

The ability to control balance during walking is a critical precondition for minimizing fall risk, but this ability is compromised in persons with lower-limb absence because of reduced sensory feedback mechanisms and inability to actively modulate prosthesis mechanical function. Consequently, these individuals are at increased fall risk compared with nondisabled individuals. A number of gait pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 47 9  شماره 

صفحات  -

تاریخ انتشار 2010