Change of sagittal spinal alignment and its association with pain and function after lumbar surgery augmented with an interspinous implant

نویسندگان

  • Rebecca J. Crawford
  • Quentin J. Malone
  • Roger I. Price
چکیده

BACKGROUND Interspinous spacer/implants like the Device for Intervertebral Assisted Motion (DIAM™) are controversially yet commonly used in the surgical treatment of lumbar degenerative pathologies. Criticism is based on ill-defined indications, lack of superiority over decompression, and a poorly understood mechanical effect. Yet, continued use by surgeons implies their perceived clinical merit. We examined radiographic spinal alignment for 12 months, and pain and function for 24 months, after DIAM-augmented surgery to improve the understanding of the mechanical effect relating to clinical outcomes in patients. METHODS We undertook a single-surgeon prospective, longitudinal study of 40 patients (20 F, 20 M) who received DIAM-augmented surgery in treatment of their symptomatic lumbar degenerative condition. Outcomes measured included sagittal spinal alignment (lumbar lordosis, sacral inclination, primary (PDA), supradjacent (SDA) disc angles, and regional sagittal balance (RSB; standing lateral radiographs), and back and leg pain (visual analogue scale; VAS) and function (Oswestry Disability Index; ODI). Responders were identified as those with clinically meaningful improvement to pain (>20%) and function (>15%) at 24 months postoperatively; features of sagittal spinal alignment between responders and non-responders were examined. RESULTS Sagittal alignment was unchanged at 12 months. At 6 weeks postoperatively, PDA (mean (SD)) reduced by 2.2° (4.0°; p < 0.01) and more-so in back pain non-responders (3.8° (3.2°)) than responders (0.7° (4.4°); p < 0.05). Positive preoperative RSB in responders (26.7Rmm (42.3Rmm); Rmm is a system-relative measure) decreased at 6 weeks (by 3.1Rmm (9.1Rmm)). Non-responders had a negative RSB preoperatively (-1.0Rmm (32.0Rmm)) and increased at 6 weeks (11.2Rmm (15.5Rmm); p < 0.05). Clinically meaningful improvement for the whole cohort for back pain and function were observed to 24 months (back pain: 25.0% (28.0); function: 15.4% (17.6); both p < 0.0001). CONCLUSIONS Unaltered sagittal alignment at 12 months was not related to symptoms after DIAM-augmented lumbar surgery. Subtle early flattening at the index disc angle was not maintained. Preoperative and early post-operative sagittal alignment may indicate response after DIAM-augmented surgery for mixed lumbar pathologies. Further investigation toward defining indications and patient suitability is warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fusion after interspinous device placement.

Lumbar interspinous devices are intended to unload the facet joints, restore foraminal height, lower intradisk pressure, and provide motion-preserving stabilization. They are an alternative treatment for patients with spinal degeneration and have increased in popularity in recent years. To the authors' knowledge, heterotopic ossification has not been previously reported around an interspinous d...

متن کامل

The cost effectiveness of dynamic and static interspinous spacer for lumbar spinal stenosis compared with laminectomy

Background: The present study aims to evaluate the cost-effectiveness of Dynamic Interspinous Spacer (Coflex&reg;) and Static Spacer (X-STOP &reg;) compared to Laminectomy (LAMI) in patients with lumbar spinal stenosis. &nbsp; Methods: A decision-analysis model was developed to estimate the cost-effectiveness. The effectiveness parameters were obtained from a systematic literature review in ...

متن کامل

The Felix-trial. Double-blind randomization of interspinous implant or bony decompression for treatment of spinal stenosis related intermittent neurogenic claudication

BACKGROUND Decompressive laminotomy is the standard surgical procedure in the treatment of patients with canal stenosis related intermittent neurogenic claudication. New techniques, such as interspinous process implants, claim a shorter hospital stay, less post-operative pain and equal long-term functional outcome. A comparative (cost-) effectiveness study has not been performed yet. This proto...

متن کامل

Treatment of 44 Cases With Lumbar Spine Stenosis and Degenerative Instability: Outcomes of Surgical Intervention

Background and Aim: Degenerative lumbar spine disease can lead to lumbar spine instability. The patients can present with Low Back Pain (LBP), radicular pain, and motor and sensory dysfunction. Age >50, female sex and pregnancies are among prevalent risk factors. The degeneration process usually starts from the intervertebral discs progressing to involve facet joints, ligaments, and vertebral b...

متن کامل

One-year Outcome Evaluation after Interspinous Implantation for Degenerative Spinal Stenosis with Segmental Instability

The authors hypothesized that the placement of the interspinous implant would show a similar clinical outcome to the posterior lumbar interbody fusion (PLIF) in patients having spinal stenosis with mild segmental instability and that this method would be superior to PLIF without significantly affecting degeneration at the adjacent segments. Forty two adult patients having degenerative spinal st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017