Measuring phacoemulsification groove depth using probe tip dimensions and biometry lens thickness readings

نویسندگان

  • Kevin Dunne
  • Alex J Buller
چکیده

AIM To describe a useful technique utilizing lens thickness from biometric data as well as phacoemulsification (phaco) probe tip dimensions, in order to more accurately determine safe groove depth during divide and conquer techniques for cataract surgery. METHODS Single center, selection of patients for cataract surgery deemed low risk and suitable for surgical teaching cases. Individual lens thickness measurements from biometry were calculated with known phaco tip dimensions to give an individualized safe number of phaco tip depths for grooving during divide and conquer. This technique was then applied during cataract surgery. RESULTS Utilization of this technique allows calculation and determination of an appropriate number of phaco tip depths of grooving for each individual patient. This technique was applied as a teaching tool for surgical trainees, with subsequent successful safe cataract surgeries completed. No posterior capsule ruptures were noted for these cases. CONCLUSION By combining the biometric measurements of an individual patient's lens thickness together with known phaco tip dimensions, individualized safe groove depths can be theoretically determined and applied during divide and conquer cataract surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.

PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicon...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry.

PURPOSE To compare central corneal thickness (CCT), anterior chamber depth (ACD), and keratometry (K) readings measured using optical low-coherence reflectometry (OLCR) biometry and high-resolution rotating Scheimpflug photography. SETTING Eye Hospital of Wenzhou Medical College, Wenzhou, China. DESIGN Comparative case series. METHODS The CCT, ACD endothelium to lens, ACD epithelium to le...

متن کامل

The Use of Femtosecond Laser-Assisted Capsulotomy Is Challenging in Patients With Phacomorphic Glaucoma.

To the Editor: Acute phacomorphic glaucoma occurs secondarily to an increased anteroposterior lens thickness that narrows the iridocorneal angle. Optic neuropathy is preventable with early recognition and treatment of the disease, but a sudden rise in intraocular pressure (IOP) can lead to irreversible visual loss in the affected eye.1-3 We evaluated the efficacy of femtosecond laser–assisted c...

متن کامل

Accuracy of intraocular lens power calculations using the Zeiss IOL master. A prospective study.

PURPOSE Partial Coherence Interferometry (PCI) is a fast, noncontact method to calculate lens implant power for cataract surgery. It has been reported as a potentially more accurate method than ultrasound biometry. Prospective study of the refractive outcomes of a consecutive series of patients undergoing phacoemulsification surgery with preoperative biometry by both ultrasound A-scan and PCI. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016