Occupational asthma to gel flux containing dodecanedioic acid.

نویسندگان

  • V C Moore
  • S Manney
  • A D Vellore
  • P S Burge
چکیده

Most occupational asthma from electronic solder fluxes is due to colophony (1, 2). We report the first case of occupational asthma to electronic colophony-free gel flux predominantly containing dodecanedioic acid. The patient worked as an electronics instructor from 1999; he initially used solder wire and a separate flux (both colophony). In 2002, he changed to a colophony-free solder wire (predominantly palmitic acid) and a separate gel flux. In 2004, he developed work-related stuffy nose and dyspnoea. This became worse in 2005 when he woke up twice a night and had a blocked nose, wheeze and sputum for the first 2 h after waking. He was worse in the evening after soldering or the night following soldering. He had no asthma, hay fever or eczema in childhood. His father had occupational asthma from corn dust, but his sister had no asthma. He smoked seven to 10 cigarettes per day since age 17 and gave up 6 weeks before being seen in clinic. He had negative skin tests to all common environmental allergens. He completed serial peak expiratory flow (PEF) measurements every 2 h for a total of 4 weeks. When plotted in Oasys (3), the record showed large deteriorations in PEF (declining up to 120 l/min from mean rest PEF) when he visited the soldering bays and intermittent smaller deteriorations when working in the office. The record was scored by the Oasys work effect index (3) as 3.00 (probable occupational asthma; a score of >2.50 has a sensitivity of 75% and specificity of 94%; 3). The area between the curves (ABC) plot (4) in Oasys analysed the two exposures separately and gave an ABC from waking score of 56 l/min/h in the soldering bay and 5 l/min for the office work (an ABC score of ‡15 l/min/h has a sensitivity of 69% and specificity of 100% for occupational asthma diagnosis; 4). His mean work day diurnal variation was 21% and mean rest day diurnal variation was 12%. His exhaled nitric oxide (FENO) level while exposed was 14.3 ppb (Aerocrine Niox at 50 ml/s). He was admitted for specific inhalation challenge testing to both solder wires and fluxes. He melted approximately 5 m of solder wire (using an iron heated to 370 C) spread over three challenges totalling 70 min. For the fluxes, he dipped the soldering iron into the flux approximately every 10 s, letting it fume into the challenge chamber after each insertion. For the colophony flux, he did this over three challenges totalling 17 min and for only 8 min when using the colophony-free gel flux. Figure 1 shows the results of the colophony and dodecanedioic acid fluxes. His forced expiratory volume in 1 s (FEV1) fell by a maximum of 23% from baseline when he was exposed to the dodecanedioic acid flux. He was negative to the colophony wire and wire containing predominantly palmitic acid. His nonspecific reactivity was >4800 lg of methacholine (via the Yan method) prechallenge, becoming measurable postchallenge at 3490 lg. Two years after removal from exposure and while working as an apprenticeship manager without soldering exposure, his asthma continues, but is no longer work-related and his FENO remains normal at 10.7 ppb. Dodecanedioic acid has an asthma hazard index of 0.94 using the chemical asthma hazard assessment programme (5); a value >0.5 has a high probability of being an asthmagen. Other noncolophony based fluxes such as palmitic acid and adipic acid (previously described in a pharmaceutical worker; 6) also have high hazard indexes (0.92 and 0.75 respectively).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Occupational asthma due to a widely used soft solder flux not containing colophony.

A 19 year old woman presented with symptoms suggestive of occupational asthma. The causative agent was thought to be a soft solder flux, which did not contain colophony. The diagnosis was established by specific inhalation challenge tests, which demonstrated both late asthmatic reactions and short-lived increases in airway responsiveness.

متن کامل

Occupational asthma in a factory making flux-cored solder containing colophony.

The prevalence of work-related wheeze and breathlessness was measured in factory employees manufacturing flux-cored solder. The flux contained colophony which was heated in the production process, exposing the workers to colophony fumes. Measurement of colophony in the breathing zone defined three grades of exposure with median levels of 1.92 mg/m3 (six subjects), 0.02 mg/m3 (14 subjects), and ...

متن کامل

Asthma caused by potassium aluminium tetrafluoride: a case series

The objective of this study is to describe a case-series of potassium aluminium tetrafluoride (KAlF(4))-induced occupational asthma (OA) and/or occupational rhinitis (OR). The study involves five patients from a heat-exchanger production line who were examined (including specific inhalation challenge tests) for suspected OA and/or OR caused by a flux containing almost 100% KAlF(4) - with fluori...

متن کامل

Mechanisms of occupational asthma.

BACKGROUND The pathogenesis and the pathologic alterations of occupational asthma are similar to those of nonoccupational asthma. Occupational asthma may therefore represent a useful model of "human asthma" to investigate mechanisms and pathophysiology of asthma in general. In an occupational setting the cause and onset of asthma may be easily identified, and the natural history may be examined...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Allergy

دوره 64 7  شماره 

صفحات  -

تاریخ انتشار 2009