Reliability of musculoskeletal ultrasound imaging to measure supraspinatus tendon thickness in healthy subjects

نویسندگان

  • Ashfaq Ahmad
  • Mohammad A. Mohseni Bandpei
  • S. Amir Gilani
  • Arooj Munawar
  • Ishaq Ahmed
  • Fahad Tanveer
چکیده

[Purpose] The purpose of this study was to assess intra-rater and inter-rater reliability of musculoskeletal ultrasound (MSKUS) as a tool to measure supraspinatus tendon thickness in healthy subjects. [Subjects and Methods] Twenty healthy subjects were assessed in similar sitting position. Two experienced musculoskeletal ultrasound specialists measured supraspinatus tendon thickness. Tendon was measured twice in one day by each of two raters with an interval of one hour for within day reliability and was re-measured following one week for between days reliability. Data analysis was performed using the intraclass correlation coefficient (ICC) and standard error of measurement (SEM). [Results] Results reflected excellent within day intra-rater and inter-rater reliability with Mean ± standard deviation (SD)=5.14 ± 0.83 and 5.17 ± 0.78, ICC (2,1)=0.89-0.93 and ICC (2,2)=0.98 (0.95-0.99) and SEM=0.18-0.18 and 0.17 while between days intra-rater rater and inter-rater reliability with Mean ± SD=5.14 ± 0.83 and 5.17 ± 0.78, ICC(2,1)=0.88-0.90 and ICC(2,2)=0.95 (0.88-0.98), SEM=0.17-0.38 and 0.17 [Conclusion] The results of the current study indicate that MSKUS is a reliable tool for measuring supraspinatus tendon thickness in healthy subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative and absolute reliability of ultrasound measurements for the thickness of the soft tissue around the shoulder joint of young normal subjects

[Purpose] The purpose of this study was to examine the reliability of ultrasound measurements by analyzing the relative reliability and absolute reliability when measuring soft tissue thickness around the shoulder joint. [Subjects and Methods] Eleven healthy young adults (22 shoulders) participated in this study. Thickness of the supraspinatus tendon, subacromial bursa, and biceps tendon was me...

متن کامل

Ultrasonic examination of biceps and supraspinatus tendons in patients with chronic hemodialysis, referring to Rasoul Akram Hospital in Tehran at 2019-2020

Introduction: Tendiopathy is defined as an overuse injury that is histologically associated with tenocyte proliferation, collagen fiber degradation, increased non-collagen matrix, fluid accumulation between fibers, capillary proliferation, and calcification. Early diagnosis of tendonopathies Conservative treatments are necessary to prevent severe tendon damage or even rupture. Ultrasound is a n...

متن کامل

Ultrasound measurements on acromio-humeral distance and supraspinatus tendon thickness: test-retest reliability and correlations with shoulder rotational strengths.

OBJECTIVES To establish the test-retest reliability of ultrasound measurements on acromio-humeral distance (AHD) and supraspinatus tendon thickness; and to explore their relationships with shoulder rotational strengths. DESIGN Test-retest observational study. METHODS Thirty-seven individuals (age: 21.5±1.4 years) participated in this study. Twenty-four were University volleyball players wit...

متن کامل

Intra-rater reliability of sonographic measurement of the upper trapezius, supraspinatus and deltoid muscles in women with frozen shoulder and healthy women

Background:  Some studies show that frozen shoulder is due to the pathologic changes in the muscles around the shoulder. Measurement of the ultrasonic thickness of a muscle is a method for measuring the muscle changes. There is no study about the reliability of measurement of the muscle’s ultrasonic thickness around the shoulder in patients with frozen shoulder. The present study aims to invest...

متن کامل

Ultrasound assessment for grading structural tendon changes in supraspinatus tendinopathy: an inter-rater reliability study

AIM To evaluate the inter-rater reliability of measuring structural changes in the tendon of patients, clinically diagnosed with supraspinatus tendinopathy (cases) and healthy participants (controls), on ultrasound (US) images captured by standardised procedures. METHODS A total of 40 participants (24 patients) were included for assessing inter-rater reliability of measurements of fibrillar d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2017