Patient radiation protection covers for head CT scans - a clinical evaluation of their effectiveness.

نویسندگان

  • M Liebmann
  • T Lüllau
  • A Kluge
  • B Poppe
  • H von Boetticher
چکیده

PURPOSE Although the use of thyroid shields for patients for head CT examinations is reasonable and even required by German regulations, so far available shields are often not used due to difficult applicability. New shields that are easier to use and therefore may gain wider acceptance and more frequent use are now available. In this work two new patient shields are investigated regarding their dose reduction effectiveness and applicability and compared to a thyroid/sternum shield typically used as a part of personal protective equipment. MATERIALS AND METHODS The reduction of organ doses for thyroid, sternum and mamma were measured with thermoluminescence detectors in an anthropomorphic female phantom. Additionally, the influence of the length or position of the overview scan at the beginning of the CT examination was taken into account. RESULTS Depending on the patient shield, a reduction of the organ doses for thyroid of 5 - 24 %, for sternum of 25 - 48 % and for mamma of 25 - 70 % could be found. A shift of 25 mm in the cranial direction for the overview scan resulted in a reduction of these organ doses of 12 - 15 %. CONCLUSION Patient shields for cranial CT examinations provide a considerable dose reduction. New models are easily applied and no decrease in image quality through reconstruction artifacts could be found. Therefore, it is advised to use shields which are applied upon the patient without the need to be wrapped around the neck and the overview scan should be positioned as close as possible to the examined region. KEY POINTS • New shields provide a compromise between usability and radiation protection.• Patient shields reduce organ doses even when not directly exposed.• The overview scan contributes considerably to out of field organ doses.• Shielding factors are greatly influenced by the positioning of the examination field.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Occupational Radiation Dose in One Year for Operators Working in CT Scan Centers

Introduction: Becuase of the most radiation dose receiving by human is related to medical radiation exposures, and also Computed Tomography (CT) is a special type of radiography that is one of the main method of radiation exposure today, and it's growing increasingly. Therefore, radio technologists working in CT scan imaging centers, are at risk of radiation. Due to the high am...

متن کامل

Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography

Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...

متن کامل

Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels

Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...

متن کامل

Thyroid dose and dose reduction method from CT scan of head and neck

Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...

متن کامل

Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa

Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

دوره 186 11  شماره 

صفحات  -