3160 Mitigate B 1 + inhomogeneity by the combination of RF shimming and B 1 + remapping using nonlinear gradient coils

نویسندگان

  • Yi-Cheng Hsu
  • Ying-Hua Chu
  • Riccardo Lattanzi
  • Daniel K Sodickson
  • Fa-Hsuan Lin
چکیده

Mitigate B1+ inhomogeneity by the combination of RF shimming and B1+ remapping using nonlinear gradient coils Yi-Cheng Hsu, Ying-Hua Chu, Riccardo Lattanzi, Daniel K Sodickson, and Fa-Hsuan Lin Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, The Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, NY, United States, Aalto University, Finland

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B ‐ mapping and B inhomogeneity correction at high field THÈSE NO 6582 ( 2015 ) ÉCOLE POLYTECHNIQUE FÉDÉRALE DE LAUSANNE

Magnetic resonance imaging is a modern imaging technique that allows anatomical images used in many medical diagnosis to be acquired in a completely non-invasive way. MR images acquired at the highest strength of the main magnetic field B0 are of interest since they highly benefit from the increased signal to noise ratio which is proportional to B0. At ultra high field strengths (B0 ≥ 7 Tesla) ...

متن کامل

Exploring the limits of RF shimming for high-field MRI of the human head.

Several methods have been proposed for overcoming the effects of radiofrequency (RF) magnetic field inhomogeneity in high-field MRI. Some of these methods rely at least in part on the ability to independently control magnitude and phase of different drives in either one multielement RF coil or in different RF coils in a transmit array. The adjustment of these drive magnitudes and phases alone t...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Outer Volume Suppression (OVS) for Single Voxel Spectroscopy (SVS) at 7 Tesla using interleaved B1 shim settings

Introduction High-field magnetic resonance spectroscopy (MRS) has the potential to provide enhanced neurochemical information based on increased sensitivity and higher spectral resolution. However, problems arising in high-field magnetic resonance imaging (MRI), such as more pronounced B0 and B1 inhomogeneities, may decrease spectral resolution and ultimately the quantification accuracy. A mult...

متن کامل

Slab selective, regularized RF shimming

Introduction RF shimming is a well-known technique, where amplitudes and phases of a transmit RF coil array are optimized to obtain a homogeneous B1 profile, i.e., to compensate wave propagation effects at main fields of 3T or above (see, e.g., [1]). Among other anatomies, legs are particularly prone to wave propagation effects due to their bi-cylindrical geometry, resulting in significant sign...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013