Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement.

نویسندگان

  • Farhad Bakhtiary
  • Mirko Schiemann
  • Omer Dzemali
  • Selami Dogan
  • Volker Schächinger
  • Hans Ackermann
  • Anton Moritz
  • Peter Kleine
چکیده

OBJECTIVES This prospective-randomized study investigated the effect of aortic valve design and patient-prosthesis mismatch (PPM) on coronary flow reserve (CFR) after mechanical or biological aortic valve replacement (AVR) in patients with aortic stenosis (AS). BACKGROUND Coronary flow reserve may be an important parameter of long-term survival after AVR in patients with AS. Reduced CFR may contribute to more cardiovascular events and greater rates of mortality. METHODS A total of 48 patients undergoing AVR underwent magnetic resonance imaging for the measurement of coronary flow preoperatively, 5 days postoperatively, and at 6-month follow-up with measurement of CFR. Patients scheduled for mechanical AVR were randomized to a tilting disc or bileaflet prosthesis (n = 12 in each group). For biological AVR, patients were scheduled to receive a stented (n = 12) or stentless (n = 12) valve. Patients also underwent echocardiography with measurement of transvalvular pressure gradients and left ventricular mass regression. RESULTS Postoperatively, coronary flow increased significantly in all groups (p < 0.001). Only stentless valves demonstrated a normal CFR (3.4 +/- 0.3 vs. 2.3 +/- 0.1 for stented biological valves, 2.1 +/- 0.2 for tilting disc, and 2.2 +/- 0.3 for bileaflet mechanical valves). Patient-prosthesis mismatch with an indexed effective orifice area <0.85 cm2/m2 led to decreased rates of CFR in the tilting disc, stentless, and stented groups. Pressure gradients were 14 +/- 3 mm Hg for tilting disc, 12 +/- 4 mm Hg for bileaflet, 19 +/- 6 mm Hg for stented, and 10 +/- 4 mm Hg for stentless valves. CONCLUSIONS Normalization of CFR after AVR in patients with AS was observed only for stentless valves. Coronary flow reserve might explain the excellent long-term results for stentless valves. (Impact of Patient-Prosthesis Mismatch on Coronary Flow Reserve; http://www.clinicaltrials.gov/ct/show/NCT00310947?order=1; NCT00310947).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Prosthesis-Patient Mismatch

I n this issue of iJACC, Dayan et al. (1) published a meta-analysis of prosthesis-patient mismatch (PPM) after aortic valve replacement from 58 studies involving 40,381 patients, mostly after surgical aortic valve replacement (SAVR). Their major findings were as follows: 1) moderate or greater (indexed effective orifice area [iEOA] <0.85 cm/m) PPM was associated with increased perioperative mor...

متن کامل

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

[Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis].

INTRODUCTION AND OBJECTIVES The clinical impact of patient-prosthesis mismatch on the outcome in octogenarians who undergo surgery for aortic valve replacement due to severe stenosis is unknown. Our objective was to quantify the frequency of some degree of patient-prosthesis mismatch and its impact on mortality and life quality. METHODS We analyzed all the octogenarian patients who underwent ...

متن کامل

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 49 7  شماره 

صفحات  -

تاریخ انتشار 2007