Hemoglobin interference with urinary Bence Jones protein analysis on electrophoresis.

نویسندگان

  • G A Hobbs
  • S S Levinson
چکیده

Two cases are described which show that on urine protein electrophoresis a paraprotein owing to hemoglobin cannot be distinguished from a Bence Jones protein. A simple method is described for confirming the presence of hemoglobin: a densitometric scan of the electrophoretogram at 415 nm, in which hemoglobin absorbs in a band coincident with the restriction. Furthermore, it is shown that other serum proteins, elevated levels of bilirubin, and Bence Jones protein do not interfere with this detection system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical applications of immunofixation: a more sensitive technique for the detection of Bence Jones protein.

Immunofixation in agarose gel has been compared with agarose electrophoresis for the detection of Bence Jones protein in urine. The technique has a sensitivity between five and 10 times greater than electrophoresis and allows the identification of multiple Bence Jones proteins and Bence Jones proteins with fast mobility in the presence of other urinary proteins. In four out of 12 patients studi...

متن کامل

Interference of polyclonal free light chains with identification of Bence Jones proteins.

We present a case in which kappa free light chains caused difficulty in interpreting classical urinary immunoelectrophoresis, but immunofixation electrophoresis (IFE) demonstrated the presence of a lambda-Bence Jones protein. Analysis of the urine by Ouchterlony double diffusion and IFE after gel-filtration chromatography showed that the difficulty was caused by the presence of large amounts of...

متن کامل

Sodium dodecyl sulfate-agarose gel electrophoresis of urinary proteins: application to multiple myeloma.

We evaluated a new sodium dodecyl sulfate-agarose gel electrophoresis (SDS-AGE) for urinary protein analysis in patients with multiple myeloma (MM; n = 47; ages, 62 +/- 2 years, mean +/- SE). Abnormal proteinuria (mean = 1872 +/- 360 mg/24 h) was present in 95% of the samples; 75% of the patients had some sign of renal dysfunction (glomerular and/or tubular) according to their SDS-AGE pattern. ...

متن کامل

Primary Amyloidosis with Plasmacytic Dyscrasia and a Tetramer of Bence Jones Type Lambda Globulin in the Serum and Urine

An abnormal protein has been isolated ported occurrence of a urinary Bence from both the serum and urine of a paJones tetramer. The sedimentation coeftient with generalized amyloidosis and ficient of the protein was 5.OS, and its plasmacytic dyscrasia. Immunological molecular weight 79,000. Reduction and and biochemical techniques were used to alkylation, electrophoresis, and ultracendemonstrat...

متن کامل

Primary amyloidosis iwith plasmacytic dyscrasia and a tetramer of Bence Jones type lambda globulin in the serum and urine.

An abnormal protein has been isolated ported occurrence of a urinary Bence from both the serum and urine of a paJones tetramer. The sedimentation coeftient with generalized amyloidosis and ficient of the protein was 5.OS, and its plasmacytic dyscrasia. Immunological molecular weight 79,000. Reduction and and biochemical techniques were used to alkylation, electrophoresis, and ultracendemonstrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 1996