Evaluation of the oxi/ferm tube system with selected Gram-negative bacteria.
نویسندگان
چکیده
The Oxi/Ferm test system was evaluated for accuracy and reliability for identification of nonfermentative and oxidase-positive fermentative bacteria by using 375 bacterial strains obtained from stock culture and clinical specimens. The Oxi/Ferm system is a compartmentalized tube containing eight media to provide nine biochemical test results. When combined with the oxidase test, the results corresponding to the positive reactions are totaled and the composite number is located in the coding manual to identify the organisms. The 375 isolates studied were evaluated for accuracy of identification, using both the original and revised code manuals. In comparison with the conventional media used, there was 100% correlation in tests for hydrogen sulfide and indole production, over 96% for nitrogen gas, arginine, and urease, over 92% for xylose and dextrose oxidation, and less than 90% for citrate utilization and dextrose fermentation. There was an overall accuracy in identification of 89.3% using the original manual, with accuracy revised slightly upward to 90.7% using the revised manual. There was 100% accuracy in identification with 44.0% of the strains tested (11 species) using the original manual and with 66.1% (16 species) using the revised manual. Thirteen of the 40 original misidentifications and 14 of 35 revised misidentifications resulted from failure to code and were unidentifiable by Oxi/Ferm. The remainder were incorrectly identified or could not be differentiated from closely related strains. Eleven strains of Alcaligenes odorans were correctly identified using the original code, whereas no code was provided in the revised manual. The Oxi/Ferm system is both simple and rapid and is satisfactory for identification of the more common isolates.
منابع مشابه
Evaluation of the Oxi/Ferm tube system for identification of nonfermentative Gram-negative bacilli.
The Oxi/Ferm tube system designed for identification of oxidative-fermentative gram-negative bacteria was evaluated for identification of nonfermentative gram-negative bacilli by comparing it with the conventional system. The nine biochemical reactions used as the initial tests in the Oxi/Ferm tube system showed a close agreement with the same conventional reactions. However, the system was onl...
متن کاملAccuracy and reproducibility of the Oxi/Ferm system in identifying a select group of unusual gram-negative bacilli.
The Oxi/Ferm (O/F) identification system was compared in a double-blind study to a conventional test battery for the characterization of 96 reference and clinical strains consisting of 83 nonfermentative and 13 oxidase-producing, fermentative gram-negative bacilli. The O/F tube and supplemental tests correctly identified 84% of the nonfermentative and 77% of the oxidase-producing, fermentative ...
متن کاملComparison of the API 20E and Oxi/Ferm systems in identification of nonfermentative and oxidase-positive fermentative bacteria.
The API 20E and Oxi/Ferm systems were tested in parallel to identify nonfermentative bacteria and oxidase-positive fermentative bacteria. Test strains consisted of consecutive clinical isolates, with stock cultures used to supplement those species infrequently recovered. The two microsystems, as well as tubes of triple sugar iron, motility, cetrimide, and oxidative glucose media, were inoculate...
متن کاملEvaluation of two rapid methods for identification of commonly encountered nonfermenting or oxidase-positive, Gram-negative rods.
The ability of the expanded API-20E and the Oxi-Ferm System to identify 176 isolates of nonfermenting or oxidase-positive, gram-negative rods from 17 species or groups was studied. The expanded API-20E, without referral to a computer reference center, was able to identify 61.4% of the isolates to the species level. If reference to the computer center was utilized, an additional 25% could be ide...
متن کاملIdentification of Gram-negative non-fermenters and oxidase-positive fermenters by the Oxi/Ferm tube.
Since the recent introduction of the Roche Oxi/Ferm Tube to the UK two identification schemes have been developed by the manufacturer for use with the kit. We evaluated the success of these two schemes in identifying 222 predominantly culture collection strains belonging to 45 taxa of non-fermenters and nine taxa of oxidase-positive fermenters. The strains were chosen to represent all the taxa ...