Rotational resistance of surface-treated mini-implants.

نویسندگان

  • Seong-Hun Kim
  • Shin-Jae Lee
  • Il-Sik Cho
  • Seong-Kyun Kim
  • Tae-Woo Kim
چکیده

OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to rotational moments of early loaded sandblasted and acid-etched (SLA) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS A randomized complete block design was used in 12 skeletally mature male beagle dogs. Ninety-six orthodontic mini-implants were tested. Two types of implants were used: some had SLA surface treatment and some had machined surfaces without coating. After 3 weeks of healing, rotational moments of 150 g were applied. The success rates, maximum torque values, angular momentum, and total energy absorbed by the bone were compared. All values were subjected to mixed-model analysis to evaluate the influence of surface treatment, rotational force direction, and site of implantation. RESULTS The maximum insertion torque and angular momentum of SLA implants were significantly lower than those of machined implants (P = .034, P = .039). The SLA implants had a significantly higher value for total removal energy than the machined implants (P = .046). However, there were no significant differences in total insertion energy, maximum removal torque, and removal angular momentum between the 2 groups. There was no significant difference between clockwise and counterclockwise rotation in all measurements. CONCLUSION SLA mini-implants showed relatively lower insertion torque value and angular momentum and higher total energy during removal than the machined implants, suggesting osseointegration of the SLA mini-implant after insertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resistance to immediate orthodontic loading of surface-treated mini-implants.

OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to orthodontic forces of immediately loaded sandblasted and acid-etched (SAE) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS Two types of mini-implants were used in the tibiae of 44 rabbits; some had an SAE surface and some had machined surfaces....

متن کامل

Evaluation of Stability of Surface-Treated Mini-Implants in Diabetic Rabbits

Introduction. The purpose of this study was to investigate effects of surface treatment of mini-implants in diabetes-induced rabbits by comparing osseointegration around mini-implants. Methods. Twelve New Zealand white rabbits were divided into two groups (alloxan-induced diabetic group and control group). A total of 48 mini-implants were placed after four weeks of diabetic induction. 24 mini-i...

متن کامل

CORROSION BEHAVIOR OF BIOACTIVATED TITANIUM DENTAL IMPLANT USING DIFFERENT CHEMICAL METHODS

At the past, damaged tissue was removed from the body of patients. But now tissue regeneration using scaffolds and implants are used to repair the damaged tissue and organs. Besides of the mechanical properties of metallic biomaterials, they suffer from bioinertness. Using some surface treatment techniques, the bioactivity and also corrosion resistance of titanium implants could be improved. In...

متن کامل

Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis.

BACKGROUND/OBJECTIVES This study investigated the biomechanical properties and bone-implant intersurface response of machined and laser surface-treated stainless steel (SS) mini-screw implants (MSIs). MATERIAL AND METHODS Forty-eight 1.3mm in diameter and 6mm long SS MSIs were divided into two groups. The control (machined surface) group received no surface treatment; the laser-treated group ...

متن کامل

Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness

OBJECTIVE This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. METHODS Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Angle orthodontist

دوره 79 5  شماره 

صفحات  -

تاریخ انتشار 2009