Filter Transmittance Measurements in the Infrared
نویسندگان
چکیده
We have set up a novel direct detection system to measure filter transmittances over an attenuation range of at least 5 decades, with relative combined standard uncertainties as low as 0.5% (1σ) per decade, in the 9 μm to 11 μm spectral region. This system, using an apparatus originally designed for a heterodyne measurement of transmittance, achieves higher accuracy at the expense of a reduced dynamic range. This independent measurement of transmittance allows verification of the heterodyne technique. Our system uses a source modulated at 30 MHz and a specially constructed high dynamic range and high accuracy lock-in amplifier capable of operation at the modulation frequency. The high modulation frequency and narrow bandwidth of the system allow thermal background radiation to be suppressed and high accuracy to be achieved. We correct for the non-ideal natures of the detector and attenuators. In particular, the detector position is scanned to reduce the effect of its spatial nonuniformity and the deflection of the transmitted beam caused by the nonparallel surfaces of the filter. We discuss the sources of systematic errors and the methodology to reduce their contribution.
منابع مشابه
Performance of a low-pass filter for far-infrared wavelengths.
We describe a low-pass filter that provides high in-band transmittance and excellent rejection at ν > 100 cm(-1). The transmittance of the filter components was measured at liquid-helium temperatures from 10 to 10,000 cm(-1). The total transmittance is >50% for ν < 50 cm(-1) and is calculated to be <10(-9) for ν > 300 cm(-1). The filter was successfully used in a liquid-helium-cooled, rocketbor...
متن کاملTechnical Note: Improved total atmospheric water vapour amount determination from near-infrared filter measurements with sun photometers
In this work we explore the effect of the contribution of the solar spectrum to the recorded signal in wavelengths outside the typical 940-nm filter’s bandwidth. We employ gaussian-shaped filters as well as actual filter transmission curves, mainly AERONET data, to study the implications imposed by the non-zero out-of-band contribution to the coefficients used to derive precipitable water from ...
متن کاملOptical Filter Transmittance Measurements by a Double-Beam Spectrophotometer for Calibration of Fluorescence Detector AUGER Filter Samples
An experimental setup and procedure for accurate transmittance measurements of candidate filters for the Auger Fluorescence Detector is presented. For this check, we used the Hitachi U-2000 double-beam spectrophotometer (Sph) of the Chemical Department of the University of Athens (UoA). After the calibration of the Sph, we are able to observe transmittance deviations over the area of the filter...
متن کاملInteractive comment on “Improved total atmospheric water vapour amount determination fromnear-infrared filter measurements with sun photometers” by F. Mavromatakis et al
This paper describes an improvement in the derivation of integrated water vapour from sun photometer observations of the atmospheric transmission within a near-infrared wavelength band (̃ 940 nm) characterized by strong water vapour absorption. The improvement is obtained by better accounting for out-of-band (OOB) transmittance of the sun photometer filter. Such contribution is usually neglected...
متن کاملNarrowband filters for the FUV range
We address the design, fabrication, and characterization of transmittance filters for the Ionosphere Photometer instrument (IP), developed by the Center for Space Science and Applied Research (CSSAR). IP, a payload of Feng-Yun 3D meteorological satellite, to be launched on 2016, is aimed to perform photometry measurements of Earth’s ionosphere by the analysis of the OI (135.6 nm) spectral line ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 98 شماره
صفحات -
تاریخ انتشار 1993