BACKGROUND Carotid artery stenting (CAS) has recently emerged as a potential alternative to carotid endarterectomy. Cerebral embolization is the most devastating complication of CAS, and the echogenicity of carotid plaque has been indicated as one of the risk factors involved. This is the first study to analyze the role of a computer-assisted highly reproducible index of echogenicity, namely the gray-scale median (GSM), on the risk of stroke during CAS. METHODS AND RESULTS The Imaging in Carotid Angioplasty and Risk of Stroke (ICAROS) registry included 418 cases of CAS collected from 11 international centers. An echographic evaluation of carotid plaque with GSM measurement was made preprocedurally. The onset of neurological deficits during the procedure and the postprocedural period was recorded. The overall rate of neurological complications was 3.6%: minor strokes, 2.2%, and major stroke, 1.4%. There were 11 of 155 strokes (7.1%) in patients with GSM < or =25 and 4 of 263 (1.5%) in patients with GSM >25 (P=0.005). Patients with severe stenosis (> or =85%) had a higher rate of stroke (P=0.03). The effectiveness of brain protection devices was confirmed in those with GSM >25 (P=0.01) but not in those with GSM < or =25. Multivariate analysis revealed that GSM (OR, 7.11; P=0.002) and rate of stenosis (OR, 5.76; P=0.010) are independent predictors of stroke. CONCLUSIONS Carotid plaque echolucency, as measured by GSM < or =25, increases the risk of stroke in CAS. The inclusion of echolucency measured as GSM in the planning of any endovascular procedure of carotid lesions allows stratification of patients at different risks of complications in CAS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carotid plaque echolucency predicts the risk of stroke in carotid stenting according to the type of brain protection device and the learning curve.

Carotid Plaque Echolucency Predicts the Risk of Stroke in Carotid Stenting According to the Type of Brain Protection Device and the Learning Curve To the Editor: Dr Reiter analyzed the relationship between carotid plaque morphology and the risk of stroke after carotid artery stenting (CAS), showing that the grayscale median (GSM) is not associated with adverse outcome.1 In the ICAROS Study, we ...

متن کامل

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion

Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...

متن کامل

Association between high sensitivity C-reactive protein (hs-CRP) levels and the risk of major adverse cardiovascular events (MACE) and/or microembolic signals after carotid angioplasty and stenting

Background: To evaluate the association between pre/post-procedural high sensitive C-reactive protein (hs-CRP) level and hs-CRP difference, and the risk of major adverse cardiovascular events (MACE) or new diffusion-weighted MRI lesions after carotid angioplasty and stenting (CAS). Methods: In this study, conducted in 2016 in Shiraz (Iran), patients who underwent diagnostic angiography and CAS...

متن کامل

Plaque echolucency and stroke risk in asymptomatic carotid stenosis: a systematic review and meta-analysis.

BACKGROUND AND PURPOSE Ultrasonographic plaque echolucency has been studied as a stroke risk marker in carotid atherosclerotic disease. We performed a systematic review and meta-analysis to summarize the association between ultrasound-determined carotid plaque echolucency and future ipsilateral stroke risk. METHODS We searched the medical literature for studies evaluating the association betw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 110 6  شماره 

صفحات  -