Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial.

نویسندگان

  • Solveig Halldorsdottir
  • Mary Ellen Warchal-Windham
  • Jane F Wallace
  • Scott Pardo
  • Joan Lee Parkes
  • David A Simmons
چکیده

BACKGROUND This study evaluated differences in accuracy between the CONTOUR® NEXT EZ (EZ) blood glucose monitoring system (BGMS) and four other BGMSs [ACCU-CHEK® Aviva (ACAP), FreeStyle Freedom Lite® (FFL), ONE TOUCH® Ultra®2 (OTU2), and TRUEtrack® (TT)]. METHODS Up to three capillary blood samples (N = 393) were collected from 146 subjects with and without diabetes. One sample per subject was tested with fresh (natural) blood; the other samples were glycolyzed to lower blood glucose to <70 mg/dl. Meter results were compared with results from plasma from the same sample tested on a Yellow Springs Instruments (YSI) 2300 STAT PlusTM glucose analyzer. Blood glucose monitoring system accuracy was compared using mean absolute relative difference (MARD; from laboratory reference method results) and other analyses. Separate analyses on fresh (natural) samples only were conducted to determine potential effects of glycolysis on MARD values of systems utilizing glucose-oxidase-based test strip chemistry. RESULTS Across the tested glucose range, the EZ had the lowest MARD of 4.7%; the ACAP, FFL, OTU2, and TT had MARD values of 6.3%, 18.3%, 23.4%, and 26.2%, respectively. For samples with glucose concentrations <70 mg/dl, the EZ had the lowest MARD (0.65%), compared with the ACAP (2.5%), FFL (18.3%), OTU2 (22.4%), and TT (33.2%) systems. CONCLUSIONS The EZ had the lowest MARD across the tested glucose ranges when compared with four other BGMSs when all samples were analyzed as well as when natural samples only were analyzed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of "Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial".

In an article in Journal of Diabetes Science and Technology, Halldorsdottir and coauthors examined the accuracy of five blood glucose monitoring systems (BGMSs) in a study sponsored by the manufacturer of the BGMS CONTOUR NEXT EZ (EZ) and found that this BGMS was the most accurate one. However, their findings must be viewed critically given that one of the BGMSs (ACCU-CHEK Aviva) was not compar...

متن کامل

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...

متن کامل

Analytical Performance and Quality Control of a Glucose Monitor System

  Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...

متن کامل

Can the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?

Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...

متن کامل

System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197.

BACKGROUND The accuracy of systems for self-monitoring of blood glucose is important, as reliable measurement results are a prerequisite for therapeutic decisions. METHODS This system accuracy evaluation study was performed according to DIN EN ISO 15197:2003 for 43 Conformité Européenne (CE)-labeled blood glucose (BG) monitoring systems. Measurement results of each system were compared with r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2013