New Developed Cylindrical TM010 Mode EPR Cavity for X-Band In Vivo Tooth Dosimetry

نویسندگان

  • Guo Junwang
  • Yuan Qingquan
  • Cong Jianbo
  • Ma Lei
  • Dong Guofu
  • Yang Guoshan
  • Wu Ke
چکیده

EPR tooth in vivo dosimetry is an attractive approach for initial triage after unexpected nuclear events. An X-band cylindrical TM010 mode resonant cavity was developed for in vivo tooth dosimetry and used in EPR applications for the first time. The cavity had a trapezoidal measuring aperture at the exact position of the cavity's cylindrical wall where strong microwave magnetic field H1 concentrated and weak microwave electric field E1 distributed. Theoretical calculations and simulations were used to design and optimize the cavity parameters. The cavity features were evaluated by measuring DPPH sample, intact incisor samples embed in a gum model and the rhesus monkey teeth. The results showed that the cavity worked at designed frequency and had the ability to make EPR spectroscopy in relative high sensitivity. Sufficient modulation amplitude and microwave power could be applied into the aperture. Radiation induced EPR signal could be observed remarkably from 1 Gy irradiated intact incisor within only 30 seconds, which was among the best in scan time and detection limit. The in vivo spectroscopy was also realized by acquiring the radiation induced EPR signal from teeth of rhesus monkey whose teeth was irradiated by dose of 2 Gy. The results suggested that the cavity was sensitive to meet the demand to assess doses of significant level in short time. This cavity provided a very potential option for the development of X-band in vivo dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhanced EPR Dose Reconstruction in Teeth

Currently electron paramagnetic resonance (EPR) retrospective biodosimetry with tooth enamel can measure doses as low as 30 mGy. This method uses commercial X-band (9.5 GHz) EPR spectrometers and specially prepared samples from tooth enamel. One of the disadvantages of X-band EPR dosimetry is the requirement to obtain isolated teeth from a cohort of interest. In vivo EPR retrospective biodosime...

متن کامل

Retrospective dosimetry using fingernail in nuclear industries: A review paper

Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...

متن کامل

Aqueous sample in an EPR cavity: sensitivity considerations.

The radial mode matching (RMM) method has been used to calculate accurately the microwave field distribution of the TE(011) mode in a spherical EPR cavity containing a linear aqueous sample, in order to understand in detail the factors affecting sensitivity in EPR measurements at X band. Specific details of the experiment were included in the calculations, such as the cavity geometry, the prese...

متن کامل

A new Q-band EPR probe for quantitative studies of even electron metalloproteins.

Existing Q-band (35 GHz) EPR spectrometers employ cylindrical cavities for more intense microwave magnetic fields B1, but are so constructed that only one orientation between the external field B and B1 is allowed, namely the B perpendicular B1 orientation, thus limiting the use of the spectrometer to measurements on Kramers spin systems (odd electron systems). We have designed and built a Q-ba...

متن کامل

EPR measurements of fingernails in Q-band

Results of a feasibility study for the use of the Q-band EPR measurements of fingernails are presented. Details of the first protocol developed for Q-band (34 GHz) EPR dose measurements in fingernails and preliminary results of a dosimetry study in comparison with the commonly-used X-band (9 GHz) are reported. It was found that 1e5 mg sample mass was sufficient for EPR measurements in fingernai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014