Tensile Mechanical Properties of Swine Cortical Mandibular Bone
نویسندگان
چکیده
Temporary orthodontic mini implants serve as anchorage devices in orthodontic treatments. Often, they are inserted in the jaw bones, between the roots of the teeth. The stability of the mini implants within the bone is one of the major factors affecting their success and, consequently, that of the orthodontic treatment. Bone mechanical properties are important for implant stability. The aim of this study was to determine the tensile properties of the alveolar and basal mandible bones in a swine model. The diametral compression test was employed to study the properties in two orthogonal directions: mesio-distal and occluso-gingival. Small cylindrical cortical bone specimens (2.6 mm diameter, 1.5 mm thickness) were obtained from 7 mandibles using a trephine drill. The sites included different locations (anterior and posterior) and aspects (buccal and lingual) for a total of 16 specimens from each mandible. The load-displacement curves were continuously monitored while loading half of the specimens in the oclluso-gingival direction and half in the mesio-distal direction. The stiffness was calculated from the linear portion of the curve. The mesio-distal direction was 31% stiffer than the occluso-gingival direction. The basal bone was 40% stiffer than the alveolar bone. The posterior zone was 46% stiffer than the anterior zone. The lingual aspect was stiffer than the buccal aspect. Although bone specimens do not behave as brittle materials, the diametral compression test can be adequately used for determining tensile behavior when only small bone specimens can be obtained. In conclusion, to obtain maximal orthodontic mini implant stability, the force components on the implants should be oriented mostly in the mesio-distal direction.
منابع مشابه
An investigation of tensile strength of Ti6Al4V titanium screw inside femur bone using finite element and experimental tests
The geometric optimization of orthopedic screws can considerably increase their orthopedic efficiency. Due to the high geometric parameters of orthopedic screws, a finite element simulation is an effective tool for analyzing and forecasting the effect of the parameters on the load-bearing capacity of different types of screws and bones. Thus, in the present study, the tensile strength of a typi...
متن کاملHuman Bone strength Evaluation through different Mechanical Tests
Bone mineral density [BMD] generally correlates with bone strength. BMD testing is used to assess bone density and diagnose osteoporosis. The correlation between CT numbers and mechanical property estimated from cortical bone were found to be low (r2<0.2) and cancellous bone were found to be higher (r2>0.6). The specific relationship depending on the types of bone, that predict elastic module f...
متن کاملRegional Variation of Mechanical Properties in Human Mandibular Subchondral Bone Tissue
Introduction: The temporomandibular joint (TMJ) is a synovial joint that has a fibrocartilaginous articular disc located between the articular cartilage of the articular eminence of the temporal bone and the mandibular condyle. As masticatory muscles maintain the integrity of the TMJ, the components of the TMJ are constantly compressed during occlusion. During mastication, muscle contractions a...
متن کاملLongitudinal variation in mechanical competence of bone along the avian humerus.
Vickers microhardness tests were used to gauge the mechanical "competence" (ability to resist bending and failure) of cortical and trabecular bone along the humeri of three bird species. Hardness was greatest at the mid-length portion of the shaft. The mean hardness of trabeculae, where present, was between 78.7 and 90.9% of that of the adjacent cortical bone. The possible causes of this are br...
متن کاملA mechanical and computational investigation on the effects of conduit orientation on the strength of massive bone allografts.
Structural bone allografts are used to reconstruct large skeletal defects resulting from trauma, tumor resection, or revision arthroplasty. Though used for over a century, bone allografts suffer from a high rate of mechanical failure due to limited graft revitalization even after extended periods in vivo. The current study evaluated the mechanical properties of longitudinally perforated cortica...
متن کامل