Ferrozine iron and total iron-binding capacity method adapted to the ABA-100 Bichromatic Analyzer.

نویسندگان

  • L Mori
  • A Bekkering
  • J Traini
  • L Vanderlinden
چکیده

A sensitive method (Clin. Chem. 26: 327--331, 1980) for serum iron, in which the color reagent Ferrozine is used, is modified and adapted to the Abbott ABA-100 discrete analyzer. The standard curve is linear to at least 10 mg/L and the method showed day-to-day precision (CV) of 2.4% for a 1.03 mg/L sample (n = 63) and 1.9% for a 2.13 mg/L sample (n = 63). Lower values were obtained than with the modified continuous-flow technique of Giovanniello et al., but the correlation was good (r = 0.98). Bilirubin and copper do not interfere; hemoglobin and gross lipemia interfere only slightly. The total iron-binding capacity, based on Ramsay's method, was evaluated with regard to the effect of adding various amounts of magnesium carbonate. Results led us to use a ratio of approximately 180 mg of magnesium carbonate to each 5 micrograms of excess iron added. Day-to-day, the method for total iron-binding capacity gave a CV of 3.1% for a 2.55 mg/L sample, 2.8% for a 3.63 mg/L sample.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An autoanalyzer procedure for serum iron and total iron-binding capacity, with use of ferrozine.

An AutoAnalyzer method has been developed in which the recently introduced reagent for iron, 3. (2.pyridyl).5,6.bis(4.phenylsulfonic acid).1,2,4.triazine (“ferrozine”), is used. With the Technicon colorimeter or Gilford 300-N spectrophotometer in use, sampling rates may be 30/h or 50/h, respectively. Sample volume is 0.8 ml, and measurements are made at 560 nm. A procedure for measuring total i...

متن کامل

An Accurate Spectrophotom etric Method for Serum Iron and Iron-B inding Capacity without Deproteinization or C entrifugation*!

A simple, direct semi-micro method has been developed for serum iron and latent iron-binding capacity. For total serum iron, into a one cm cuvet are pipetted (a ) 1.5 ml of Na acetate buffer (pH 4.5) containing Na ascorbate and (b ) 0.3 ml of serum. The serum blank absorbance is measured at 562 nm, and 0.2 ml of ferrozine color reagent is added. After incubation (42°, 20 min), the absorbance is...

متن کامل

Modification of fully automated total iron-binding capacity (TIBC) assay in serum and comparison with dimension TIBC method.

BACKGROUND We previously reported the development of a fully automated assay for total iron-binding capacity (TIBC) in serum, using a multipurpose automated analyzer. However, this method requires four different reagents and is thus useful only with a limited number of available analyzers. We simplified our original assay and compared the analytical performance of the modified method with that ...

متن کامل

Micro-scale enzymic determination of ethanol in plasma with a discrete analyzer, the ABA-100.

An enzymic method for estimating ethanol has been adapted to the Abbott Bichromatic Analyzer-100. Fully automated, the method can accommodate up to 192 assays per hour. It requires only 2.5 muL of plasma and therefore is applicable to analysis for ethanol in blood sampled by finger-prick.

متن کامل

Effects of Alpha-Lipoid Acid on Serum Iron, Total Iron Binding Capacity and Hematological Indices in β-Thalassemia Major Patients: A Cross Over Clinical Trial

Background and Objectives: Accumulation of iron is the most common consequences of repeated blood transfusions in β-thalassemia major patients. Iron chelating effects of alpha-lipoic acid have been reported by several studies. The aim of this study was to investigate effects of supplementation with alpha-lipoic acid, as a chelator, on serum iron and hematological indices in these patients.  Ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 8  شماره 

صفحات  -

تاریخ انتشار 1981