Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry.

نویسندگان

  • Fujio Araki
  • Yuji Hanyu
  • Miyoko Fukuoka
  • Kenji Matsumoto
  • Masahiko Okumura
  • Hiroshi Oguchi
چکیده

The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic-therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water-to-plastic ionization conversion factor k(pl) for PW and PWDT was computed for several commonly used Farmer-type ionization chambers with different wall materials in the range of 4-18 MV photon beams. For electron beams, a depth-scaling factor c(pl) and a chamber-dependent fluence correction factor h(pl) for both phantoms were also calculated in combination with NACP-02 and Roos plane-parallel ionization chambers in the range of 4-18 MeV. The h(pl) values for the plane-parallel chambers were evaluated from the electron fluence correction factor phi(pl)w and wall correction factors P(wall,w) and P(wall,pl) for a combination of water or plastic materials. The calculated k(pl) and h(pl) values were verified by comparison with the measured values. A set of k(pl) values computed for the Farmer-type chambers was equal to unity within 0.5% for PW and PWDT in photon beams. The k(pl) values also agreed within their combined uncertainty with the measured data. For electron beams, the c(pl) values computed for PW and PWDT were from 0.998 to 1.000 and from 0.992 to 0.997, respectively, in the range of 4-18 MeV. The phi(pl)w values for PW and PWDT were from 0.998 to 1.001 and from 1.004 to 1.001, respectively, at a reference depth in the range of 4-18 MeV. The difference in P(wall) between water and plastic materials for the plane-parallel chambers was 0.8% at a maximum. Finally, h(pl) values evaluated for plastic materials were equal to unity within 0.6% for NACP-02 and Roos chambers. The h(pl) values also agreed within their combined uncertainty with the measured data. The absorbed dose to water from ionization chamber measurements in PW and PWDT plastic materials corresponds to that in water within 1%. Both phantoms can thus be used as a substitute for water for photon and electron dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation

Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...

متن کامل

Comparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

متن کامل

Application of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom

Background: In treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by ICRU in report 24. The experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. Therefore, inhomogeneity corrections should be used in treatment pla...

متن کامل

Evaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study

Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

متن کامل

Estimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods

Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 36 7  شماره 

صفحات  -

تاریخ انتشار 2009