Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient
نویسندگان
چکیده
BACKGROUND Cardiac output (CO) monitoring is a valuable tool for the diagnosis and management of critically ill patients. In the critical care setting, few studies have evaluated the level of agreement between CO estimated by transthoracic echocardiography (CO-TTE) and that measured by the reference method, pulmonary artery catheter (CO-PAC). The objective of the present study was to evaluate the precision and accuracy of CO-TTE relative to CO-PAC and the ability of transthoracic echocardiography to track variations in CO, in critically ill mechanically ventilated patients. METHODS Thirty-eight mechanically ventilated patients fitted with a PAC were included in a prospective observational study performed in a 16-bed university hospital ICU. CO-PAC was measured via intermittent thermodilution. Simultaneously, a second investigator used standard-view TTE to estimate CO-TTE as the product of stroke volume and the heart rate obtained during the measurement of the subaortic velocity time integral. RESULTS Sixty-four pairs of CO-PAC and CO-TTE measurements were compared. The two measurements were significantly correlated (r = 0.95; p < 0.0001). The median bias was 0.2 L/min, the limits of agreement (LOAs) were -1.3 and 1.8 L/min, and the percentage error was 25%. The precision was 8% for CO-PAC and 9% for CO-TTE. Twenty-six pairs of ΔCO measurements were compared. There was a significant correlation between ΔCO-PAC and ΔCO-TTE (r = 0.92; p < 0.0001). The median bias was -0.1 L/min and the LOAs were -1.3 and +1.2 L/min. With a 15% exclusion zone, the four-quadrant plot had a concordance rate of 94%. With a 0.5 L/min exclusion zone, the polar plot had a mean polar angle of 1.0° and a percentage error LOAs of -26.8 to 28.8°. The concordance rate was 100% between 30 and -30°. When using CO-TTE to detect an increase in ΔCO-PAC of more than 10%, the area under the receiving operating characteristic curve (95% CI) was 0.82 (0.62-0.94) (p < 0.001). A ΔCO-TTE of more than 8% yielded a sensitivity of 88% and specificity of 66% for detecting a ΔCO-PAC of more than 10%. CONCLUSION In critically ill mechanically ventilated patients, CO-TTE is an accurate and precise method for estimating CO. Furthermore, CO-TTE can accurately track variations in CO.
منابع مشابه
Can Transthoracic Echocardiography Be Used to Predict Fluid Responsiveness in the Critically Ill Patient? A Systematic Review
Introduction. We systematically evaluated the use of transthoracic echocardiography in the assessment of dynamic markers of preload to predict fluid responsiveness in the critically ill adult patient. Methods. Studies in the critically ill using transthoracic echocardiography (TTE) to predict a response in stroke volume or cardiac output to a fluid load were selected. Selection was limited to E...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملHemodynamic Comparison Between Right Heart Catheterization and Transthoracic Echocardiography in the Critically Ill Patients: A Prospective Study
Background: Tranthoracic echocardiography (TTE) is increasingly utilized in the management of critically ill patients in whom right heart catheterization (RHC) was frequently used in the past. We tested the hypothesis that bedside TTE can substitute for RHC for determining the etiology of cardiopulmonary compromise in critically ill patients when initial clinical assessment is limited. Methods:...
متن کاملAccuracy of cardiac output estimations by transthoracic echocardiography compared with an accepted method of thermodilution, the pulmonary artery catheter, in the critically ill patients
Methods Prospective observational cohort study. A total of 42 consecutive critically ill patients who required hemodynamic monitoring with pulmonary artery catheter were enrolled over a period of 18 months. Demographic data, reason for admission, comorbidities, APACHE II, SOFA, need for vasoactive drugs and acceptability of the ultrasound measurements, were analyzed. In each patient, three PWD-...
متن کامل[Role of echocardiography in the hemodynamic monitorization of critical patients].
The use of echocardiography in intensive care units in shock patients allows us to measure various hemodynamic variables in an accurate and a non-invasive manner. By using echocardiography not only as a diagnostic technique but also as a tool for continuous hemodynamic monitorization, the intensivist can evaluate various aspects of shock states, such as cardiac output and fluid responsiveness, ...
متن کامل