An Automated Size Recognition Technique for Acetabular Implant in Total Hip Replacement
نویسندگان
چکیده
Preoperative templating in Total Hip Replacement (THR) is a method to estimate the optimal size and position of the implant. Today, observational (manual) size recognition techniques are still used to find a suitable implant for the patient. Therefore, a digital and automated technique should be developed so that the implant size recognition process can be effectively implemented. For this purpose, we have introduced the new technique for acetabular implant size recognition in THR preoperative planning based on the diameter of acetabulum size. This technique enables the surgeon to recognise a digital acetabular implant size automatically. Ten randomly selected X-rays of unidentified patients were used to test the accuracy and utility of an automated implant size recognition technique. Based on the testing result, the new technique yielded very close results to those obtained by the observational method in nine studies (90%).
منابع مشابه
A randomised study comparing resection of acetabular bone at resurfacing and total hip replacement.
We have undertaken a prospective, randomised study to compare conservation of acetabular bone after total hip replacement and resurfacing arthroplasty of the hip. We randomly assigned 210 hips to one of the two treatment groups. Uncemented, press-fit acetabular components were used for both. No significant difference was found in the mean diameter of acetabular implant inserted in the groups (5...
متن کاملInfluence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty.
Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite ...
متن کاملUsing acetabular fossa as a guide for anticipated inclination of uncemented cup in total hip replacement.
Positions of acetabular implant generally are considered to be major causative factors of dislocation. Accurate and consistent achievement of the preoperatively anticipated orientation of the acetabular cup is a great challenge in total hip replacement (THR). In the present study, we investigated the surgical application of acetabular fossa as a guide for anticipated inclination of uncemented c...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملReconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement
Developmental dysplasia of the hip (DDH) or congenital hip dysplasia (CDH) is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DD...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CoRR
دوره abs/1105.0079 شماره
صفحات -
تاریخ انتشار 2011