International Intercomparisons of Photometric Base Units

نویسنده

  • Klaus D. Mielenz
چکیده

National Bureau of Standards Gaithersburg, MD 20899 In order to evaluate the worldwide consistency of practical implementations of the 1979 redefinition of the candela, the Consultative Committee for Photometry and Radiometry (CCPR) has conducted an international intercomparison of photometric base units. The intercomparison showed 0.8% agreement (one standard deviation) of independent luminousintensity scale realizations by 15 national laboratories, and 0.6% agreement of luminous-flux scale realizations by 11 laboratories. The NBS candela and lumen agreed with the world mean within quoted uncertainty limits, and were shown to be consistent with one another within 0.5%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Detector-Based Candela Scale and Related Photometric Calibration Procedures at NIST

The candela, one of the SI base units, has been realized by using absolutely calibrated detectors rather than sources. A group of eight photometers was constructed using silicon photodiodes, precision apertures, and glass filters for V (λ) match. Their absolute spectral responsivities were calibrated against the NIST absolute spectral responsivity scale. The measurement chain has been significa...

متن کامل

Evaluation of the annual Canadian biodosimetry network intercomparisons

PURPOSE To evaluate the importance of annual intercomparisons for maintaining the capacity and capabilities of a well-established biodosimetry network in conjunction with assessing efficient and effective analysis methods for emergency response. MATERIALS AND METHODS Annual intercomparisons were conducted between laboratories in the Canadian National Biological Dosimetry Response Plan. Interc...

متن کامل

IAEA Intercomparisons in the Frame of the Occupational Radiation Protection Programme

The IAEA safety activities to support the assessment of occupational exposure through a comprehensive set of Safety Guides, Safety Reports and other related documents will soon be completed. Several intercomparison exercises were organized by the IAEA on the determination of radionuclides in human urine samples, whole body counting and external dosimetry. These previous intercomparison exercise...

متن کامل

High-throughput photometric titrimetry based on a feedback-based and subsequent fixed triangular wave-controlled flow ratiometry.

The principle of flow ratiometry for high-throughput titration, which we recently proposed for potentiometric titration, was extended to photometric titration. The flow rate (FB) of a base solution containing an acid-base indicator was linearly varied in response to a control voltage (Vc) generated from a computer. With the total (acid + base) flow rate (FT) being kept constant, the base soluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010