Decoupled Feed Forward Voltage Oriented Controller for DFIG under Balanced and Unbalanced Fault Conditions
نویسندگان
چکیده
As Wind Power Penetration increases continuously in total Power Generation, the wind turbines are necessary to stay connected to grid even under grid disturbances. An enhanced control strategy for DFIG is proposed in the present paper to meet the latest grid codes set by grid operators. The Decoupled Current Controller implemented in Grid Voltage oriented reference frame is applied to Grid Side Converter (GSC) to improve the dynamic performance of DFIG. The Proposed scheme enhances the Low Voltage ride through capability of Wind farm by providing reactive Power support under adverse grid conditions. The Proposed scheme also counteracts the ripples in DC Link voltage, stator/rotor currents and stator/reactive power to fulfill the grid code commitments in weak grid.Simulation results are presented to verify the feasibility and robustness of the proposed control scheme.
منابع مشابه
Reactive and Active Power Control of Grid WECS Based on DFIG and Energy Storage System under both Balanced and Unbalanced Grid Conditions
This paper focuses on improving the active and reactive power control of Wind Energy Conversion System (WECS) by employing the Battery Energy Storage System (BESS) and controlling the frequency and voltage regulation instantaneously. The proposed power control scheme is composed of two control loops so that they are implemented and designed for active power control and controlling the reactive ...
متن کاملLow Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کاملPassivity-Based Control of a Doubly Fed Induction Generator System under Unbalanced Grid Voltage Conditions
According to the theory of passivity-based control (PBC), this paper establishes a port-controlled Hamiltonian system with dissipation (PCHD) model for a doubly fed induction generator (DFIG) system under unbalanced grid voltage conditions and proposes a method of interconnection and damping assignment passivity-based control (IDA-PBC) of the system under such conditions. By using this method, ...
متن کاملEffect of Doubly Fed Induction GeneratorTidal Current Turbines on Stability of a Distribution Grid under Unbalanced Voltage Conditions
This paper analyses the effects of doubly fed induction generator (DFIG) tidal current turbines on a distribution grid under unbalanced voltage conditions of the grid. A dynamic model of an electrical power system under the unbalanced network is described in the paper, aiming to compare the system performance when connected with and without DFIG at the same location in a distribution grid. Exte...
متن کاملUnbalanced-Grid-Fault Ride-Through Control for a Doubly Fed Induction Generator Wind Turbine with Series Grid-Side Converter
The grid codes now require doubly fed induction generator (DFIG) wind turbines having the “low voltage ride-through (LVRT)” capability. However, a traditional DFIG with a partially rated back-to-back converter has inherent difficulties to ride through the grid faults, especially for the unbalanced grid faults. Modifications to the traditional DFIG configuration for ride-through have become nece...
متن کامل