Study of Radiation Effects in -Ray Irradiated Power VDMOSFET by DCIV Technique
نویسنده
چکیده
Direct-current current–voltage (DCIV) measurement was used to monitor interface recombination currents in 137 -ray irradiated commercial power VDMOSFETs. The data are correlated with the subthreshold I–V data and charge-pumping current data, which are obtained after various biased-annealing steps. The DCIV method is found to be a convenient technique in monitoring the radiation effects in power VDMOSFET devices. Various parameters measured with the DCIV technique are discussed in conjunction with the charge-pumping data and the data from the midgap method. A two-dimensional MOS device simulator, MINIMOS, was used to illustrate the DCIV data. The simulation results illustrate well the dependence of the measurable DCIV parameters on various radiation-induced physical parameters such as interface-trap density, fixed oxide charge density, and surface recombination velocity. A biased annealing experiment in nonirradiated virgin devices showed that the second current peak in the double peak structure of the DCIV data may be associated with the slow-frequency (300 6000 Hz) charge-pumping signal.
منابع مشابه
DCIV and Spectral Charge-Pumping Studies of -Ray and X-ray Irradiated Power VDMOSFET Devices
This paper reports the total dose effects and post-irradiation anneal effects on the two recombination current peaks and the bottom current in commercial power VDMOSFET devices irradiated with Cs -ray or X-ray radiation. The two interface recombination current peaks show a slightly different rate of increase as a function of the radiation dose. Slightly different diode ideality factors are foun...
متن کاملA comparison of ionizing radiation and high field stress effects in n-channel power vertical double-diffused metal-oxide-semiconductor field-effect transistors
n-channel power vertical double-diffused metal-oxide-semiconductor field-effect-transistor (VDMOSFET) devices were subjected to a high electric field stress or to a x-ray radiation. The current-voltage and capacitance-voltage measurements show that the channel-side interface and the drain-side interface are affected differently in the case of high electric field stress, whereas the interfaces a...
متن کاملEvaluation of Gamma Ray Effects on Total Phenolic Contents, Antioxidants and Antibacterial Activities of Cichorium Intybus L
ABSTRACT The efficacy of gamma irradiation is well versed as a method of decontamination for food and herbal resources. In the present study, Cichorium intybus L. roots were irradiated at multiple doses of 1, 2, 4, 6, 8 and 10 kGy by a cobalt-60 irradiator. The irradiated and non-irradiated control samples were evaluated for total phenolic contents, chlorogenic acid assay, 2,2-diphenyl-1-...
متن کاملEffect of low dose X-ray on membrane fluidity of thalassemic red blood cells
Background: Chest X-ray is one of the examinations required for an annual health checkup. The interaction of radiation to the medium produces free radicals, which consequently causes biological changes either structural or properties of the cells. Whether the radiation from Chest X-ray upright technique affects the plasma membrane fluidity of thalassemic red blood cells (RBCs) is still unclear....
متن کاملDetermination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...
متن کامل