Discriminant Analysis of Trace Element Distribution in Normal and Malignant Human Tissues1
نویسندگان
چکیده
Discriminant analysis of 16 trace element levels measured by ultramicro energy dispersive X-ray fluorescence in malignant and histologically normal human breast, colon, and lung tissues is shown to be a potentially valuable methodology for making malignant-normal and tis sue-type classifications. Linear composites of trace elements producing optimal malignantnormal discriminations are found to differ with respect to the number and identity of elements included in the composite for breast, colon, and lung tissues. Nine-, 10-, and 11-element discriminant functions produced overall classification accuracies of 98% for breast, 100% for colon, and 100% for lung tissues, respectively. Elements found to be most important in distinguishing between malignant and normal tissues are ( 'a, Rb, and Zn in breast, Ca, Zn, and Fe in colon, and Fe, Mn, and Cu in lung samples. Three-group discriminations between breast, colon, and lung tissues were 85% accurate using trace element levels in paired malignant-normal tissues and 91% accurate using trace element levels in tumor tissues only.
منابع مشابه
Discriminant analysis of trace element distribution in normal and malignant human tissues.
Discriminant analysis of 16 trace element levels measured by ultramicro energy dispersive X-ray fluorescence in malignant and histologically normal human breast, colon, and lung tissues is shown to be a potentially valuable methodology for making malignant-normal and tissue-type classifications. Linear composites of trace elements producing optimal malignant-normal discriminations are found to ...
متن کاملInvestigation of heavy trace elements in neoplastic and non-neoplastic human thyroid tissue: A study by proton-induced X-ray emissions.
Background: Within the context of developing techniques to facilitate the diagnosis of the thyroid diseases, the elemental composition of pathological thyroid tissue (neoplastic and non-neoplastic) was investigated by proton induced X-ray emission. The PIXE has been widely used as a sensitive technique for trace elemental analysis in both biological and medical fields. Materials and Methods: Th...
متن کاملEffects of statistical distribution of joint trace length on the stability of tunnel excavated in jointed rock mass
The rock masses in a construction site of underground cavern are generally not continuous, due to the presence of discontinuities, such as bedding, joints, faults, and fractures. The performance of an underground cavern is principally ruled by the mechanical behaviors of the discontinuities in the vicinity of the cavern. During underground excavation, many surrounding rock failures have close r...
متن کاملA pixe analysis for measuring the trace elements concentration in breast tissue of Iranian women
Background: A powerful and improved technique, Proton Induced X-ray Emission (PIXE) has been performed-yielding the elemental composition of 17 samples of surgically excised malignant and normal tumors of breast tissue. The samples without any further process as thick targets were put on capton foil backing. There are no homogenizing processes. The PIXE spectra analysis was performed using he n...
متن کاملA Survey on the Accumulation of Trace Metals in Local Fishermen Hair from the Northern Persian Gulf
The concentrations of trace metals in hair of fishermen from the Persian Gulf region were assessed todetect the relationships between element levels in hair and potential factors influencing these relationships.The hair of 19 fishermen were sampled from six stations in the Persian Gulf (Nirogah, Dayyer, Lengeh and Bandar Abbas in Khuzestan, Bushehr and Hormozgan provincesanalyzed by Inductively...
متن کامل