The Reliability and Reproducibility of Corneal Confocal Microscopy in Children.

نویسندگان

  • Danièle Pacaud
  • Kenneth G Romanchuk
  • Mitra Tavakoli
  • Claire Gougeon
  • Heidi Virtanen
  • Maryam Ferdousi
  • Alberto Nettel-Aguirre
  • Jean K Mah
  • Rayaz A Malik
چکیده

PURPOSE To assess the image and patient level interrater agreement and repeatability within 1 month for corneal nerve fiber length (CNFL) measured using in vivo corneal confocal microscopy (IVCCM) in children. METHODS Seventy-one subjects (mean [SD] age 14.3 [2.6] years, range 8-18 years; 44 with type 1 diabetes and 27 controls; 36 males and 35 females) were included. 547 images (∼6 images per subject) were analyzed manually by two independent and masked observers. One-month repeat visit images were analyzed by a single masked observer in 21 patients. Automated image analysis was then performed using a specialized computerized software (ACCMetrics). RESULTS For CNFL, the ICC (95% CI) were 0.94 (0.93-0.95) for image-level, 0.86 (0.78-0.91) for patient-level, and 0.88 (0.72-0.95) for the 1-month repeat assessment, and the Bland-Altman plots showed minimal bias between observers. Although there was excellent agreement between manual and automated analysis according to an ICC 0.89 (0.82-0.93), the Bland-Altman plot showed a consistent bias with manual measurements providing higher readings. CONCLUSIONS In vivo corneal confocal microscopy image analysis shows good reproducibility with excellent intraindividual and interindividual variability in pediatric subjects. Since the image-level reproducibility is stronger than the patient-level reproducibility, refinement of the method for image selection will likely further increase the robustness of this novel, rapid, and noninvasive approach to detect early neuropathy in children with diabetes. Further studies on the use of IVCCM to identify early subclinical neuropathy in children are indicated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

Confocal microscopy of corneal sub-basal nerve plexus: a quantitative and qualitative analysis in healthy and pathologic eyes.

PURPOSE To validate corneal sub-basal nerve plexus examination by in vivo corneal confocal microscopy. METHODS Five parameters of corneal sub-basal nerve plexus in 250 human eyes (nerve fiber length, number of fibers, number of beadings, branching pattern, fiber tortuosity) acquired using in vivo corneal confocal microscopy (Confoscan 4.0; NIDEK Co Ltd) were analyzed. The first operator repea...

متن کامل

گزارش سه مورد کراتیت آکانتامبایی در یزد

Acanthamoeba keratitis is a vision- threatening infection and the most important risk factors are contact lenses Characteristic symptoms include disproportionately severe ocular pain, epithelial ulcer, ring stromal infiltrate and resistance to antimicrobial treatment. The aim is to report the first cases of Acanthamoeba keratitis in Yazd in a retrospective study confirmed on histopathological ...

متن کامل

Corneal confocal microscopy is efficient, well-tolerated, and reproducible.

In order to develop an efficient, reproducible, and well-tolerated protocol for assessing corneal innervation, 11 normal subjects underwent corneal confocal microscopy (CCM) using a Heidelberg Retinal Tomography III microscope. Five standardized locations were sampled in the left eye and one centrally in the right. The protocol was repeated 1-4 weeks later. A blinded technician measured nerve f...

متن کامل

Assessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy

BACKGROUND The aim was to compare the repeatability, reproducibility and inherent precision of ultrasound pachymetry (USP), noncontact specular microscopy (SP-2000P) and the Confoscan 4 confocal microscope (z-ring CS4) in measuring endothelial cell density (ECD), coefficient of variation of cell size (CV), and central corneal thickness (CCT) in normal eyes. METHODS In this prospective study, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 56 9  شماره 

صفحات  -

تاریخ انتشار 2015