Evaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
نویسندگان
چکیده
BACKGROUND Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic technique in C/S. METHODS This study was carried out on 60 parturient patients undergoing elective C/S. A standardized anesthetic technique was applied: induction with Thiopental (4-5 mg/kg) and Succinylcholine (1.5-2 mg/kg) as well as maintenance with O2, N2O, and isoflurane. Electrocardiogram, heart rate, blood pressure, Spo2, end-tidal isoflurane concentration, BIS, and any clinical signs of inadequate depth of anesthesia such as movement, sweating, lacrimation, coughing, and jerking were continuously monitored and recorded at 16 fixed time points during anesthesia. RESULTS A median BIS of less than 70 (range: 42-68) was obtained on all occasions during surgery; however, at each milestone, at least 20% of the patients had BIS values above 60. Hemodynamic parameters increased significantly in some patients, especially during laryngoscopy and intubation. No patient experienced recall or awareness. CONCLUSION The currently used general anesthetic technique in our center appears inadequate in some milestones to reliably produce BIS values less than 60, which are associated with lower risk of awareness. Therefore, with respect to such desirable outcomes as good Apgar and clinical status in neonates, we would recommend the application of this method (if confirmed by further studies) through larger dosages of anesthetic agents.
منابع مشابه
Evaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...
متن کاملEvaluation of Mexiletine Effect on Bispectral Index Changes and Hemodynamic Responses to Endotracheal Intubation and During General Anesthesia
Background &Objective: Plaryngoscopy and tracheal intubation increase not only blood pressure and heart rate but also Bispectral Index (BIS) of the patients. In this study, hemodynamic and BIS changes were surveyed after tracheal intubation and during general anesthesia followed by mexiletine prescription . Materials & Methods: In this study, 50 patients aged between 20 and 60 who were ca...
متن کاملNEUROSCIENCES AND NEUROANAESTHESIA Surveyon the adequacyof depth of anaesthesia with bispectral index and isolated forearm technique in elective Caesarean section under general anaesthesia with sevoflurane
Editor’s key points † Bispectral index (BIS) monitoring is commonly used to monitor depth of anaesthesia. † The authors studied parturients in whom standard techniques were used for general anaesthesia for Caesarean section. † The isolated forearm test was used to study the ability of the BIS to detect consciousness. † BIS values below 60 were commonly associated with IFT responses, particularl...
متن کاملEvaluation of the reasons of fear in spinal anesthesia during cesarean section
Background: Spinal anesthesia is a type of neuraxial anesthesia that brings ample benefits. However, due to the fear of this type of anesthesia, many pregnant people refuse to experience it. In this study, we aimed to investigate the levels and causes of fear of spinal anesthesia in candidates for cesarean section. Methods: The current study is a cross-sctional study performed on 67 patients u...
متن کاملThe IFT (isolated forearm technique) and consciousness.
1 Zand F, Hadavi SMR, Chohedri A, Sabetian P. Survey on the adequacy of depth of anaesthesia with bispectral index and isolated forearm technique in elective Caesarean section under general anaesthesia with sevoflurane. Br J Anaesth 2014; 112: 871–8 2 Tunstall ME. The reduction of amnesic wakefulness during caesarean section. Anaesthesia 1979; 34: 316–9 3 Russell IF. The ability of bispectral i...