Loop-Mediated Isothermal Amplification Targeting Actin DNA of Trichomonas vaginalis

نویسندگان

  • Youn-Kyoung Goo
  • Won-Sik Shin
  • Hye-Won Yang
  • So-Young Joo
  • Su-Min Song
  • Jae-Sook Ryu
  • Hyun-Hee Kong
  • Won-Ki Lee
  • Dong-Il Chung
  • Yeonchul Hong
چکیده

Trichomoniasis caused by Trichomonas vaginalis is a common sexually transmitted disease. Its association with several health problems, including preterm birth, pelvic inflammatory disease, cervical cancer, and transmission of human immunodeficiency virus, emphasizes the importance of improved access to early and accurate detection of T. vaginalis. In this study, a rapid and efficient loop-mediated isothermal amplification-based method for the detection of T. vaginalis was developed and validated, using vaginal swab specimens from subjects suspected to have trichomoniasis. The LAMP assay targeting the actin gene was highly sensitive with detection limits of 1 trichomonad and 1 pg of T. vaginalis DNA per reaction, and specifically amplified the target gene only from T. vaginalis. Validation of this assay showed that it had the highest sensitivity and better agreement with PCR (used as the gold standard) compared to microscopy and multiplex PCR. This study showed that the LAMP assay, targeting the actin gene, could be used to diagnose early infections of T. vaginalis. Thus, we have provided an alternative molecular diagnostic tool and a point-of-care test that may help to prevent trichomoniasis transmission and associated complications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loop-mediated isothermal amplification (LAMP) assay for the rapid detection of the sexually-transmitted parasite, Trichomonas vaginalis.

A loop-mediated isothermal amplification (LAMP) assay was developed to detect the sexually-transmitted parasite, Trichomonas vaginalis in vaginal swabs. The presence of T. vaginalis was detected from 121 female sex workers attending a social hygiene clinic in Balibago, Angeles City, Pampanga, Philippines using culture, polymerase chain reaction (PCR), and the developed LAMP assay. The high anal...

متن کامل

Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)

Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...

متن کامل

تشخیص بیماریها با استفاده از (Loop-Mediated Isothermal Amplification (LAMP در دامپزشکی

 مقدمه و هدف: نیاز به روشی ساده تر، با کارایی بالاتر، سریعتر و ارزانتر نسبت به روشهای موجود جهت تشخیص بیماریهای دامپزشکی روش واکنش زنجیره ای پلی مراز (PCR) ، روشی سریع و حساس می باشد که قادر است تعداد نسخه اندکی از DNA هدف را تا سطحی که توسط ژل الکترفورز قابل تشخیص باشد، تکثیر نماید.بعلت کارایی بالا و قدرت زیاد PCR ، این روش در سالهای اخیر بطور گسترده ای در تشخیص پاتوژن های مختلف بیماریزا اعم ا...

متن کامل

Determination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran

Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...

متن کامل

Determination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran

Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2016