Near fatal puerperal thrombosis on Björk-Shiley mitral valve prosthesis.
نویسندگان
چکیده
A 22-year-old woman required emergency mitral valve replacement three weeks post partum because of thrombotic obstruction of her prosthetic mitral valve. Low dose subcutaneous heparin was administered from the 17th week of pregnancy. Though there was a successful fetal outcome, heparin did not prevent thrombosis on the prosthesis and its continuation into the puerperium proved nearly fatal.
منابع مشابه
Echocardiographic assessment of left ventricular filling characteristics after mitral valve replacement with the St Jude medical prosthesis.
The major cause of late mortality and morbidity after prosthetic valve replacement is thromboembolism. The nidus for initiation of thrombus formation has been blood metal interfaces, and a new valve--the St Jude prosthesis--has therefore been developed without any metal components. We have assessed echocardiographically in 27 patients the effects of this valve on left ventricular filling charac...
متن کاملEvaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.
We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...
متن کاملHaemolysis after mitral valve replacement with the Björk-Shiley and the Lillehei-Kaster disc valve prosthesis.
The present study reports on the incidence and degree of intravascular haemolysis in 33 patients with Björk-Shiley tilting disc prosthesis and in 34 patients with Lillehei-Kaster pivoting disc valve prosthesis in the mitral position examined 12 to 24 months after the operation. Serum haptoglobin, serum lactate dehydrogenase, serum bilirubin, and haemoglobin estimations were performed. Significa...
متن کاملDoppler and two-dimensional echocardiographic diagnosis of Björk-Shiley prosthetic valve malfunction: importance of interventricular septal motion and the timing of onset of valve flow.
In a 69 year old woman with a "sticking" Björk-Shiley mitral prosthesis, the diagnosis was suggested by both the two-dimensional and the Doppler ultrasound examinations. In particular, the findings of early diastolic paradoxic septal motion, intermittent delayed opening of the prosthetic disc and variable timing of the onset of mitral valve inflow were believed to be diagnostic of a sticking ti...
متن کاملDoppler echocardiographic characteristics of normal and dysfunctioning prosthetic valves in the tricuspid and mitral position.
The Doppler echocardiographic characteristics of 70 prosthetic valves in 35 patients are reported. Twenty nine patients had a Björk-Shiley prosthesis in both mitral and tricuspid positions and six had Carpentier-Edwards valves in both sites. Five of the patients had abnormal tricuspid prostheses on the basis of clinical and echocardiographic criteria. Pulsed wave Doppler echocardiography was us...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 41 5 شماره
صفحات -
تاریخ انتشار 1978