Tailored magnetoelastic sensor geometry for advanced functionality in wireless biliary stent monitoring systems

نویسندگان

  • Scott R Green
  • Yogesh B Gianchandani
چکیده

This paper presents three types of wireless magnetoelastic resonant sensors with specific functionalities for monitoring sludge accumulation within biliary stents. The first design uses a geometry with a repeated cell shape that provides two well-separated resonant mode shapes and associated frequencies to permit spatial localization of mass loading. The second design implements a pattern with specific variation in feature densities to improve sensitivity to mass loading. The third design uses narrow ribbons joined by flexible couplers; this design adopts the advantages in flexibility and expandability of the other designs while maintaining the robust longitudinal mode shapes of a ribbon-shaped sensor. The sensors are batch patterned using photochemical machining from 25 μm thick 2605SA1 MetglasTM, an amorphous Fe–Si alloy. Accumulation of biliary sludge is simulated with paraffin or gelatin, and the effects of viscous bile are simulated with a range of silicone fluids. Results from the first design show that the location of mass loads can be resolved within ∼5 mm along the length of the sensor. The second design offers twice the sensitivity to mass loads (3000–36 000 ppm mg−1) of other designs. The third design provides a wide range of loading (sensitive to at least 10× the mass of the sensor) and survives compression into a 2 mm diameter tube as would be required for catheter-based delivery. (Some figures in this article are in colour only in the electronic version)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tailored magnetoelastic sensor geometry for wireless biliary stent monitoring

This paper presents three types of wireless magnetoelastic resonant sensors with specific functionalities for monitoring sludge accumulation within biliary stents. The first design uses a geometry with a repeated cell shape that provides two well-separated resonant mode shapes and associated frequencies to permit spatial localization of mass loading. The second design implements a pattern with ...

متن کامل

In situ and ex vivo evaluation of a wireless magnetoelastic biliary stent monitoring system.

This paper presents the in situ and ex vivo evaluation of a system that wirelessly monitors the accumulation of intimal tissue and sludge in a biliary stent. The sensing element, located within the stent, is a magnetoelastic resonator that is queried by a wireless radio frequency signal. The in situ testing uses a commercially-available self-expanding biliary stent enhanced with a 1 mm x 25 mm ...

متن کامل

In vivo and in situ evaluation of a wireless magnetoelastic sensor array for plastic biliary stent monitoring.

This paper presents the in vivo and in situ evaluation of a system that wirelessly monitors the accumulation of biliary sludge in a plastic biliary stent. The sensing element, located within the stent, is a passive array of magnetoelastic resonators that is queried by a wireless electromagnetic signal. The in vivo and in situ testing uses commercially-available plastic biliary stents, each enha...

متن کامل

3D Path Planning Algorithm for Mobile Anchor-Assisted Positioning in Wireless Sensor Networks

Positioning service is one of Wireless Sensor Networks’ (WSNs) fundamental services. The accurate position of the sensor nodes plays a vital role in many applications of WSNs. In this paper, a 3D positioning algorithm is being proposed, using mobile anchor node to assist sensor nodes in order to estimate their positions in a 3D geospatial environment. However, mobile anchor node’s 3D path optim...

متن کامل

Metglas–Elgiloy bi-layer, stent cell resonators for wireless monitoring of viscosity and mass loading

This paper presents the design and evaluation of magnetoelastic sensors intended for wireless monitoring of tissue accumulation in peripheral artery stents. The sensors are fabricated from 28 μm thick foils of magnetoelastic 2826MB MetglasTM, an amorphous Ni–Fe alloy. The sensor layer consists of a frame and an active resonator portion. The frame consists of 150 μm wide struts that are patterne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010