Myeloperoxidase serves as a marker of oxidative stress during single haemodialysis session using two different biocompatible dialysis membranes.

نویسندگان

  • Chia-Chao Wu
  • Jin-Shuen Chen
  • Wen-Mein Wu
  • Tung-Nan Liao
  • Pauling Chu
  • Shih-Hua Lin
  • Chien-Huei Chuang
  • Yuh-Feng Lin
چکیده

BACKGROUND There is increased oxidative stress in patients undergoing haemodialysis (HD); however, little is known of how different dialysis membranes contribute to the oxidative stress induced by the dialysis procedure per se. We therefore studied the influence of two different dialysis membranes on oxidative stress during HD. METHODS Eight patients undergoing HD three times per week were enrolled in this cross-controlled study. Patients sequentially received HD using polysulphone (PS) and regenerated cellulose (RC) dialysis membranes for 1 week each. Blood samples were collected in the last section of each hollow fibre 0, 15, 120 and 240 min after starting HD. We determined superoxide anion production derived from neutrophils, superoxide dismutase (SOD) and glutathione peroxidase (GPx) derived from washed red cells, plasma myeloperoxidase (MPO), plasma thiobarbituric acid-reactive substances (TBARS), plasma advanced oxidation protein products (AOPP) and serum 8-hydroxy-2'-deoxyguanosine (8-OHdG). RESULTS Leukocyte numbers, including neutrophils, lymphocytes and monocytes, decreased significantly after 15 min of dialysis, more so with RC than with PS membrane. For both membranes, superoxide anion production transiently increased during the first 15 min whereas the post-dialysis production was decreased. Plasma MPO levels persistently increased during dialysis with the two membranes. Moreover, the increase was more marked with RC than with PS membrane. AOPP and 8-OHdG levels increased progressively when using RC membranes. There were no significant differences in SOD, GPx, TBARS, AOPP and 8-OHdG levels between the two membranes. CONCLUSIONS The biocompatibility of the dialyser affects oxidative stress production during a single dialysis session. The measurement of MPO may serve as a reliable marker of the degree of oxidative stress induced using dialysis membranes of different biocompatibilities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oxidative stress in chronic renal failure

Oxidative stress defines an imbalance between formation of reactive oxygen species (ROS) and antioxidative defence mechanisms. In view of the profound biological effects of ROS, in recent years numerous clinical and experimental studies focused on detection of signs of oxidative stress in renal patients. There is good evidence indicating that uraemia in general is associated with enhanced oxida...

متن کامل

Acute effects of hemodialysis on oxidative stress parameters in chronic uremic patients: Comparison of two dialysis membranes

Uremic state and hemobioincompatibility are implicated in subclinical inflammation and oxidative stress and progression of atherosclerosis in the hemodialysis (HD) population. To what extent different dialysis membranes contribute to oxidative stress induced by a dialysis procedure per se is still a subject of debate. Fifteen HD patients and 15 healthy controls were enrolled in this study. Pati...

متن کامل

Dialysis filter type determines the acute effect of haemodialysis on endothelial function and oxidative stress.

BACKGROUND Endothelial function of large arteries is impaired in chronic haemodialysis patients and oxidative stress due to the dialysis procedure has been suggested as a causal factor. However, it is not clear whether different types of dialysis membranes affect endothelial function differently. Therefore we determined endothelium-dependent, flow-mediated dilatation (FMD) of the brachial arter...

متن کامل

Treatment of severe dialysis reactions with the AN69-ST membrane: biocompatibility does matter

Dialysis reactions with biocompatible membranes are rare, and complement activation has been suggested to be a culprit. We report here a case of an incident haemodialysis patient with asthma disease who experienced severe adverse reactions late into dialysis session, with different synthetic membranes (FX 80, Fresenius; Polyflux 17L, Gambro; FX 10, Fresenius; BLS 512, Bellco-Sorin). After repla...

متن کامل

پاسخ‌های همودینامیک در پی لارنگوسکوپی و لوله‌گذاری تراشه: پروپوفول در مقایسه با تیوپنتال سدیم

Background: The risk of atherosclerosis and cancer is high in hemodialysis (HD) patients. There is evidence that HD causes oxidative stress. However, the causative factors of oxidative stress are unknown. It has been suggested that HD imposes an additional oxidative stress on patients with chronic renal failure by activation of granulocytes on dialyzer membranes resulting in an imbalance betwee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2005