The last decade has seen an increasing awareness that the manner by which a compressor meets the part load conditions of residential air conditioning is a strong dete:cninant of the a.easonal SEER of the air conditioner. The compressor can reSPond to part load needs by cycling if of the single SPeed variety, by cycling between capacity levels if of the multiSPeed variety, by use of internal capacity control, or SPeed modulation for load following. A plot of load vs ambient temperature, showing the zero load temperatures for the class of buildings in which units containing the compressor will be ap~lied may be used to indicate the range of loads, and indirectly the correSPonding pressure ratios imposed on the compressor. Lines of capacity of such units may be included to approximate the percentage of "on" time for each ambient condition if the compressor is cycled, or the required level of capacity if the compressor is modulated. When the hours per year at the various ambients are added to the plot the expected period of operation of the compressor at each pressure ratio and average capacity are revealed. Large differences in compressor operating conditions are imposed by the air conditioning unit in different geographical areas, and by different heating-cooling changeover temperatures. The SEER of the unit the compressor serves thus varies widely in different locations. Information from such an analysis is very valuable in dete:cnining the optimum design of the compressor. Examples will be given in the paper for units located in Dal]as and Chicago,
منابع مشابه
Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...
متن کاملDesign and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study
In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...
متن کاملDesigning Fuzzy Controller for Air Conditioning Systems in order to Save Energy Consumption and Provide Optimal Conditions in Closed Environments (Indoors)
Today air conditioning systems have been considered by all people as one of welfarerequirements in buildings and closed environments. Since a considerable part of energy lossoccurs in ordinary modern systems, new strategies and solutions are developed in the field inorder to save amount of energy consumption and observe environmental considerations. Fuzzycontrol is one of these methods which pr...
متن کاملEvaluation of Lubricants for R410A/R407C Applications in Scroll Compressor
Sonny G. Sundaresan Copeland Corporation Sidney, Ohio, U.S.A. HCFC 22 currently used in Air-Conditioning and Heat Pump applications, is being replaced by R407C and R410A, both HFC 32 based blends. Scroll compressors are being developed to meet the improved efficiency and other system performance requirements in Air-Conditioning and Heat Pump products in North America, Europe and Asia-Pacific. L...
متن کاملPerformance and Reliability Degradation of a Residential Unitary Air Conditioning System Resulting from a Mismatch of a 1992 Air Conditioning Unit with a 15-20 Year Old Evaporator
Fred Keller Split Systems Director The National Appliance Energy Conservation Act has established a minimum efficiency of 10 SEER for residential split system air conditioners and heat pumps. Approximately 50% of residential split system air conditioners are sold as replacements for units having much lower SEER levels, typically 5-9 Btu/W·h. This investigation assessed the detrimental affects t...