Can modifications of the MDRD formula improve the estimation of glomerular filtration rate in renal allograft recipients?
نویسندگان
چکیده
BACKGROUND Two modifications of the MDRD equation [the Mayo Clinic (MC) equation and Rule's refitted (RR) MDRD formula] were proposed to overcome disadvantages of the original MDRD formula to calculate glomerular filtration rate (GFR). Additionally, a correction factor for the original MDRD formula has been introduced to adapt this formula to creatinine values measured by the isotope-dilution mass spectrometry (IDMS) method. Although precise determination of GFR is of central importance in renal transplant recipients, these equations have not been tested in these patients so far. METHODS Considering the impact of different creatinine calibrations, we analysed the MC equation and the RR-MDRD formula in comparison with the old as well as the re-expressed (IDMS traceable) MDRD equation and the Cockcroft-Gault (C-G) formula in 126 consecutive patients after kidney transplantation with respect to correlation, bias, precision, accuracy and ROC analysis. GFR was determined as technetium-diethylenetriamine pentaacetic acid ((99m)Tc-DTPA-clearance). RESULTS After adjustment to IDMS creatinine determination, the performance of the re-expressed MDRD formula improved considerably in comparison to the original MDRD equation. In comparison with the re-expressed MDRD formula bias of the MC formula and the RR-MDRD formula were significantly smaller (2.31 and -0.35 vs 3.82 ml/min/1.73 m(2)). However, precision and correlation of these formulae did not differ significantly from one another, but all equations showed a higher precision than the C-G formula (P < or = 0.006 each). The accuracies within 30% of true GFR of the MC (79.4%) and the RR-MDRD equation (84.9%) were significantly higher than those of the re-expressed MDRD formula (72.2%; P < 0.03). CONCLUSION In comparison to the original and the re-expressed MDRD formula, calculation of GFR by the MC equation and the RR-MDRD formula led to improved diagnostic performance in renal transplant recipients after adjustment of creatinine. In quotidian work both formulae can be applied to these patients. Nonetheless, to determine GFR exactly, gold standard techniques are mandatory.
منابع مشابه
Determining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels
Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...
متن کاملComparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation
Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...
متن کاملEvaluation of Glomerular Filtration Rate Estimating Formulas in Diabetic Patients with Chronic Kidney Disease
Objective: Measurement of glomerular filtration rate (GFR) is the best determinant in assessment of kidney function for diagnostic and therapeutic purposes. As extremely accurate methods of GFR measurement (i.e. Inulin clearance) are expensive and Time-consuming and due to limitations of the 24 hour urine collection method, some formula have been developed for the GFR measurement. Here we have ...
متن کاملA study of glomerular filtration rate estimation by cockcroft-gault, mdrd and ckd-epi formula in comparison with dtpa renal scan – a comparative study among live related kidney donors in south india
A study of glomerular filtration rate estimation by cockcroft-gault, mdrd and ckd-epi formula in comparison with dtpa renal scan – a comparative study among live related kidney donors in south india. a b c Original Article BACKGROUND: Renal function assessment is the most important part of donor evaluation. The Glomerular Filtration Rate (GFR) is considered to be optimal test for overall assess...
متن کاملAssociation of Glomerular Filtration Rate with Inflammation in Polycystic Ovary Syndrome
Background We aimed to estimate the glomerular filtration rate (GFR) in women with polycystic ovary syndrome (PCOS) and to determine the relationship between GFR with C-reactive protein (CRP) and uric acid. MaterialsAndMethods In this cross-sectional study, one-hundred and forty PCOS women and 60 healthy subjects were evaluated. The study was carried out at Endocrinology Outpatient Clinic, Erzu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 22 12 شماره
صفحات -
تاریخ انتشار 2007